34
IBM® xSeries 150: Installation Guide
Expansion enclosure problems
Suggested action
The SCSI expansion enclosure
used to work, but does not work
now.
Verify that:
1. The cables for all external SCSI options are connected correctly.
2. The last option in each SCSI chain, or the end of the SCSI cable, is terminated
correctly.
3. Any external SCSI option is turned on. You must turn on an external SCSI
option before turning on the server.
For more information, see your SCSI and expansion enclosure documentation.
Service processor problems
Suggested action
Netfinity Service Processor
Manager reports a general
monitor failure
Disconnect the server from all electrical sources, wait for 30 seconds, reconnect the
server to the electrical sources, and restart the server.
If a problem remains, call for service.