Function: system cache messages (202)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Aborted
Test setup error: BIOS cannot access VPD information
Action: If your server does not have the latest level of BIOS installed, update the
BIOS to the latest level and run the diagnostic program again. Refer to Chapter 7,
“Getting help, service, and information” on page 161 for information about obtaining
updates.
If the problem persists, have the system serviced.
Aborted
Test setup error: Corrupt DMI BIOS. Information in BIOS is not as expected
Action: If your server does not have the latest level of BIOS installed, update the
BIOS to the latest level and run the diagnostic program again. Refer to Chapter 7,
“Getting help, service, and information” on page 161 for information about obtaining
updates.
If the problem persists, have the system serviced.
Aborted
Test setup error: No L2 cache detected on microprocessor socket id xyz or BIOS
setup problem
where xyz identifies the microprocessor causing the error message.
Action:
1. If your server does not have the latest level of BIOS installed, update the BIOS
to the latest level and run the diagnostic program again. Refer to Chapter 7,
“Getting help, service, and information” on page 161 for information about
obtaining updates.
2. If the problem persists, replace the identified microprocessor.
If the problem persists, have the system serviced.
Aborted
Test setup error: Unknown hardware problem associated with microprocessor in
socket id xyz
where xyz identifies the microprocessor causing the error message.
Action:
1. If your server does not have the latest level of BIOS installed, update the BIOS
to the latest level and run the diagnostic program again. Refer to Chapter 7,
“Getting help, service, and information” on page 161 for information about
obtaining updates.
2. If the problem persists, replace the identified microprocessor and run the
diagnostic program again.
If the problem persists, have the system serviced.
Failed
Microprocessor in socket ID xyz
where xyz identifies the microprocessor causing the error message.
Note: The Microprocessor Error LED for the indicated microprocessor will be on.
See “Processor-board component locations” on page 101 for the location of
the LEDs and the microprocessor connectors.
Action:
1. Reseat the identified microprocessor.
2. If the problem persists, replace the identified microprocessor.
If the problem persists, have the system serviced.
Warning
Test setup error: Cache is disabled. Use system setup to enable before retrying the
test
Action: Use the Cache Control selection in the Advanced Setup menu of the
Configuration/Setup Utility program to enable the cache. (See “Advanced Setup” on
page 27.)
If the problem persists, have the system serviced.
Chapter 6. Solving problems
133
Summary of Contents for eServer 240 xSeries
Page 1: ...User s Reference xSeries 240...
Page 26: ...16 IBM xSeries User s Reference...
Page 50: ...40 IBM xSeries User s Reference...
Page 116: ...106 IBM xSeries User s Reference...
Page 170: ...160 IBM xSeries User s Reference...
Page 180: ...170 IBM xSeries User s Reference...
Page 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...