PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing controller. The hardware assumptions
made in doing so are incorrect. This error can also occur if you try to specify a mode (such as
redundancy) that conflicts with another specified mode.
Action: Make sure that your hardware configuration matches the software settings. See “PCI
Slot/Device Information” on page 28 for information on viewing and changing interrupt requests.
PCNTNW-NW-126 The group bit in the node address override was cleared.
Explanation: The IEEE address has a group bit indicating that an address belongs to a group of
stations. This bit is used only as a destination address; it cannot be used as a source address. You
tried to enter a source address with this bit set. The device driver cleared the group bit of the source
address.
Action: None necessary, message is for information only.
PCNTNW-NW-127 The local bit in the node address override was set.
Explanation: The local bit in the IEEE address format indicates that the addresses are being managed
locally. If you use the node-address-override capabilities of this device driver to enter a new address,
the local bit must be set. You entered an address without the local bit set. The device driver has set
the local bit.
Action: None necessary, message is for information only.
PCNTNW-NW-164 The device was not found.
Explanation: The device driver cannot find an Ethernet controller in the server.
Action: Verify that the Ethernet controller is enabled. (See “PCI Slot/Device Information” on page 28.)
If the Ethernet controller is enabled, go to “Diagnostic programs” on page 110 to run the diagnostic
programs.
PCNTNW-NW-165 The device was not found at IOADDRESS.
Explanation: The Ethernet controller cannot be found at the I/O address specified.
Action: The Ethernet controller does not require a parameter for the I/O address. Remove the I/O
address parameter.
PCNTNW-NW-167 PCI scan specified, device not found.
Explanation: The device driver cannot locate the Ethernet controller on the PCI bus.
Action: Verify that the Ethernet controller is enabled. (See “PCI Slot/Device Information” on page 28.)
If the problem persists, go to “Diagnostic programs” on page 110 to run the diagnostic programs.
PCNTNW-NW-180 The DMA parameter is not necessary for PCI device.
Explanation: The Ethernet controller does not require a DMA setting.
Action: None necessary, message is for information only.
138
IBM xSeries User's Reference
Summary of Contents for eServer 240 xSeries
Page 1: ...User s Reference xSeries 240...
Page 26: ...16 IBM xSeries User s Reference...
Page 50: ...40 IBM xSeries User s Reference...
Page 116: ...106 IBM xSeries User s Reference...
Page 170: ...160 IBM xSeries User s Reference...
Page 180: ...170 IBM xSeries User s Reference...
Page 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...