pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris device driver has been reset because of a device fault.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, go to “Diagnostic programs” on page 110
to run the diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris device driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings.
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
142
IBM xSeries User's Reference
Summary of Contents for eServer 240 xSeries
Page 1: ...User s Reference xSeries 240...
Page 26: ...16 IBM xSeries User s Reference...
Page 50: ...40 IBM xSeries User s Reference...
Page 116: ...106 IBM xSeries User s Reference...
Page 170: ...160 IBM xSeries User s Reference...
Page 180: ...170 IBM xSeries User s Reference...
Page 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...