In some memory configurations, the 3-3-3 beep code might sound during
POST followed by a blank display screen. If this occurs and the Boot Fail
Count feature in the Start Options of the Configuration/Setup Utility is set
to Enabled (its default setting), you must restart the server three times to
force the system BIOS to reset the memory connector or bank of
connectors from Disabled to Enabled.
5. If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation” on page 85.
Installing internal drives
Different types of drives allow your system to read multiple types of media and
store more data. Several types of drives are available, such as:
Diskette
Hard disk
CD-ROM
Tape
Internal drive bays
Internal drives are installed in bays. Your server comes with one 3.5-inch, 1.44 MB
diskette drive and one CD-ROM drive.
Tower model
1
Diskette drive bay
2
SCSI ID 0 bay
3
SCSI ID 2 bay
4
SCSI ID 3 bay
5
SCSI ID 4 bay
6
SCSI ID 8 bay
7
SCSI ID 9 bay
8
Hot-swap bays
9
CD-ROM drive bay
1
Non-hot-swap bay B
11
Non-hot-swap bay A
Chapter 4. Installing options