100
IBM® xSeries 250: User’s Reference
POST error messages
The following tables provide information about the POST error messages that can
appear during startup.
1-2-4
RAM refresh verification has failed.
Reseat the
memory
modules or
install a memory
module. If the
problem persists,
call for service.
1-3-1
First 64 Kb RAM test has failed.
1-3-2
First 64 Kb RAM parity test has failed.
3-3-1
A memory size mismatch has occurred.
3-3-3
No memory has been detected in the system.
POST message
Description
062
The server failed to boot on three consecutive attempts.
All caches are disabled. Repeatedly turning the server on and then off or resetting the server
might cause this problem.
Action:
Start the Configuration/Setup Utility program and verify that all settings are correct.
Use the Cache Control selection in the Advanced Setup menu of the
Configuration/Setup Utility program to enable the caches.
If the problem persists, call for service. When the problem is corrected, be sure to enable the
caches.
101
102
106
An error occurred during the system board and microprocessor test.
Action:
Call for service.
114
An adapter read-only memory (ROM) error occurred.
Action:
Remove the options. If you can start the server without the options installed, reinstall
each option one at a time and retest after each is reinstalled. When an option fails,
replace it.
If you cannot isolate and correct the problem, call for service.
Table 16. POST error messages.
Table 15. POST beep codes.
Summary of Contents for eServer 250 xSeries
Page 1: ...User s Reference xSeries 250...
Page 2: ......
Page 3: ...IBM IBM xSeries 250 User s Reference SC21 P902 00...
Page 8: ...vi IBM xSeries 250 User s Reference...
Page 14: ...xii IBM xSeries 250 User s Reference...
Page 24: ...10 IBM xSeries 250 User s Reference...
Page 36: ...22 IBM xSeries 250 User s Reference...
Page 108: ...94 IBM xSeries 250 User s Reference...
Page 185: ......
Page 186: ...IBM Part Number 21P9020 Printed in the United States of America 21P9 2...