Chapter 6. Solving problems
105
11xx
An error occurred during the system-board serial port test.
Action:
If you have a modem, serial printer, or other serial device attached to your server, verify
that the serial cable is connected correctly. If it is, use the following procedure:
1.
Turn off the server.
2.
Disconnect the serial cable from the serial port.
3.
Wait five seconds; then, turn on the server.
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing
information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1.
Make sure that the IRQ and I/O port assignments needed by the serial port are
available.
2.
If all interrupts are being used by adapters, you might need to remove an adapter to
make an interrupt available to the serial port, or force other adapters to share an
interrupt.
1301
Cable to Information LED panel not detected.
Action:
Make sure that the cable to the operator information panel is connected.
If the problem persists, call for service.
1302
Cable to Power and Reset pushbuttons not detected.
Action:
Make sure that the cable to the Power and Reset pushbuttons is connected.
If the problem persists, call for service.
1303
I2C cable to Power Backplane not detected.
Action:
Make sure that the cable to the power backplane is connected.
If the problem persists, call for service.
1304
Cable to Diagnostic LED panel not detected.
Action:
Make sure that the cable to the diagnostic LED panel is connected.
If the problem persists, call for service.
1600
The Advanced System Management processor is not functioning.
Action:
1.
Verify that the jumpers for the system-management processor are set correctly.
2.
Disconnect the server from all electrical sources, wait for 30 seconds, reconnect the
server to the electrical sources, and restart the server.
If the problem persists, call for service.
1601
The BIOS needs to be updated.
Action:
1.
Disconnect the server from all electrical sources, wait for 30 seconds, reconnect the
server to the electrical sources, and restart the server.
2.
If the problem persists, update the BIOS.
If the problem persists, call for service.
POST message
Description
Table 16. POST error messages.
Summary of Contents for eServer 250 xSeries
Page 1: ...User s Reference xSeries 250...
Page 2: ......
Page 3: ...IBM IBM xSeries 250 User s Reference SC21 P902 00...
Page 8: ...vi IBM xSeries 250 User s Reference...
Page 14: ...xii IBM xSeries 250 User s Reference...
Page 24: ...10 IBM xSeries 250 User s Reference...
Page 36: ...22 IBM xSeries 250 User s Reference...
Page 108: ...94 IBM xSeries 250 User s Reference...
Page 185: ......
Page 186: ...IBM Part Number 21P9020 Printed in the United States of America 21P9 2...