Blade server Ethernet controller enumeration
The enumeration of the Ethernet controllers in a blade server is operating-system
dependent. You can verify the Ethernet controller designations a blade server uses
through the operating system settings.
The routing of an Ethernet controller to a particular switch-module bay depends on
the type of blade server. You can verify which Ethernet controller is routed to which
switch-module bay by using the following test:
1. Install only one Ethernet switch module or pass-thru module, in switch-module
bay 1.
2. Make sure the ports on the switch module or pass-thru module are enabled
(
Switch Tasks
→
Management
→
Advanced Switch Management
in the
management module Web-based user interface).
3. Enable only one of the Ethernet controllers on the blade server. Note the
designation the blade server operating system has for the controller.
4. Ping an external computer on the network connected to the switch module. If
you can ping the external computer, the Ethernet controller you enabled is
associated with the switch module in switch-module bay 1. The other Ethernet
controller in the blade server is associated with the switch module in
switch-module bay 2.
If you have installed an I/O expansion card on a blade server, communications from
the option are routed to switch-module bays 3 and 4. You can verify which controller
on the card is routed to which switch-module bay by performing the above test,
using a controller on the I/O expansion card and a compatible switch module or
pass-thru module in switch bay 3 or 4.
Configuring an IDE RAID
Note:
Configuring an IDE RAID only applies to a blade server that has two IDE
hard disk drives installed.
You can configure an IDE redundant array of independent disks (RAID) array for the
blade server. Two IDE hard disk drives in the blade server can be used to
implement and manage RAID level-0 (stripe) and RAID level-1 (mirror) arrays under
operating systems that are listed on the ServerProven
®
list at http://www.ibm.com/
pc/compat/. For information about this function, see the HS20 Type 8832 Installation
and User’s Guide on the
BladeCenter Documentation
CD or the
BladeCenter T
Documentation
CD.
Important:
You must create the RAID array
before
you install the operating system
on the blade server.
18
BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer BladeCenter HS20 Type 8832
Page 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 119: ...Appendix B Safety information 109 ...
Page 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 121: ...Appendix B Safety information 111 ...
Page 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 123: ...Appendix B Safety information 113 ...
Page 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 137: ...Appendix B Safety information 127 ...
Page 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 139: ...Appendix B Safety information 129 ...
Page 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 141: ...Appendix B Safety information 131 ...
Page 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 157: ......
Page 158: ... Part Number 49Y0165 Printed in USA 1P P N 49Y0165 ...