Note:
See “System” on page 94 to determine which components should be replaced by a field service technician.
Message
Action
CPU x shut off due to over temperature
1.
Ensure that the system is being properly cooled
; see “System
reliability considerations” on page 27.
2. Replace microprocessor
x
.
Critical Blower Failure, blade server
powering down
v
See BladeCenter
Hardware Maintenance Manual
.
Power Modules are over temperature,
blade server powering down
v
See BladeCenter
Hardware Maintenance Manual
.
DASD checkout
Note:
See “System” on page 94 to determine which components should be replaced by a field service technician.
Message
Action
Hard drive x removal detected
(level-critical; hard drive x has been
removed)
v
Information only, take action as appropriate.
Undetermined problems
Note:
When troubleshooting a problem with the HS20 Type 8832, it must be
determined whether the problem is a blade server problem or a problem with
the BladeCenter unit.
v
If the BladeCenter unit contains more than one blade server and only one
of the blade servers exhibits the problem, it is likely that it is a blade
server problem.
v
If all of the blade servers exhibit the same symptom, it is probably a
BladeCenter unit problem; for more information, see the IBM BladeCenter
Hardware Maintenance Manual
.
Use the information in this section if the diagnostic tests did not identify the failure,
the devices list is incorrect, or the system is inoperative.
Damaged data in CMOS memory or damaged BIOS code can cause undetermined
problems. To reset the CMOS data, remove the battery for 15 minutes, and then
reinstall the battery. If you suspect that the BIOS code is damaged, see
“Recovering the BIOS code” on page 25.
Check the LEDs on all the power supplies of the BladeCenter unit where the blade
server is installed. If the LEDs indicate the power supplies are working correctly,
and reseating the blade server does not correct the problem, complete the following
steps:
1. Check that the front panel is connected to the system board.
2. If no LEDs on the front panel are working, replace the front panel; then, try to
power up the blade server from the BladeCenter web interface (see the
BladeCenter documentation for more information).
3. Turn off the blade server.
4. Remove the blade server and remove the cover.
90
BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide
Summary of Contents for eServer BladeCenter HS20Type 8832
Page 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 119: ...Appendix B Safety information 109...
Page 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 121: ...Appendix B Safety information 111...
Page 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 123: ...Appendix B Safety information 113...
Page 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 137: ...Appendix B Safety information 127...
Page 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 139: ...Appendix B Safety information 129...
Page 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 141: ...Appendix B Safety information 131...
Page 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 157: ......
Page 158: ...Part Number 49Y0165 Printed in USA 1P P N 49Y0165...