System board removal
When replacing the system board, you must either update the system with the
latest firmware or restore the pre-existing firmware that the customer provides on a
diskette or CD image.
Note:
v
Read “Installation guidelines” on page 27.
v
Read the safety notices at Appendix B, “Safety information,” on page 97.
v
Read “Handling static-sensitive devices” on page 27.
Complete the following steps to remove the system board:
1. Shut down the operating system and turn off the blade server (see “Turning off
the blade server” on page 9).
2. Remove the blade server from the BladeCenter (see “Removing the blade
server from the BladeCenter unit” on page 29).
3. Remove the blade server cover (see “Opening the blade server cover” on page
34) or expansion unit (see “Installing an expansion unit” on page 46).
4. Remove the blade server bezel assembly (see “Removing the blade server
bezel assembly” on page 36).
5. Remove all components (see the appropriate installation instructions and
reverse the steps) and place them on a static-protective surface for
reinstallation.
Notes:
a. A microprocessor assembly ships with a new heat sink.
b. A system board does not ship with a heat sink. When replacing the system
board and re-installing an existing microprocessor, be sure to also re-install
the heat sink (see “Thermal grease” on page 59).
603 PIN SOCKET
603 PIN SOCKET
603 PIN SOCKET
603 PIN SOCKET
Heat sink
retention
bracket
Retention bracket
screws (8 places)
System board
System board
screws (7 places)
Chapter 7. Field replaceable units
63
Summary of Contents for eServer BladeCenter HS20Type 8832
Page 1: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 18: ...8 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 64: ...54 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 66: ...56 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 118: ...108 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 119: ...Appendix B Safety information 109...
Page 120: ...110 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 121: ...Appendix B Safety information 111...
Page 122: ...112 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 123: ...Appendix B Safety information 113...
Page 124: ...114 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 136: ...126 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 137: ...Appendix B Safety information 127...
Page 138: ...128 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 139: ...Appendix B Safety information 129...
Page 140: ...130 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 141: ...Appendix B Safety information 131...
Page 146: ...136 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 152: ...142 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 156: ...146 BladeCenter HS20 Type 8832 Hardware Maintenance Manual and Troubleshooting Guide...
Page 157: ......
Page 158: ...Part Number 49Y0165 Printed in USA 1P P N 49Y0165...