Model
D10
and
Model
D20
Specifications
This
section
contains
system
specifications
for
both
the
Model
D10
and
Model
D20
I/O
subsystems.
Model
D10
Specifications
Dimensions
7311-D10
Two
7311-D10s
with
Enclosure
Height
170
mm
(6.6
in)
178
mm
(7.0
in)
Width
220
mm
(8.7
in)
445
mm
(17.5
in)
Depth
711
mm
(28.0
in)
711
mm
(28.0
in)
Weight
16.8
kg
(37
lbs)
39.1
kg
(86
lbs)
Electrical
Power
source
loading
for
two
7311-D10
(max.)
0.21
kVA
Voltage
range
200
to
240
V
ac,
(dc
not
supported)
Frequency
50
or
60
Hz
Thermal
output
(typical)
461
Btu/hr
Thermal
output
(max.)
683
Btu/hr
Power
requirements
(typical)
135
watts
Power
requirements
for
two
7311-D10
(max.)
200
watts
Power
factor
0.91
Inrush
current
²
64
amps
Maximum
altitude
3,
4
3048
m
(10000
ft.)
Temperature
Requirements
³
Operating
10
to
38°C
50
to
100°F)
Non-Operating
1
to
60°C
(34
to
140°F)
Storage
1
to
60°C
(34
to
140°F)
Humidity
Requirements
⁴
Operating
Non-Operating
Storage
(Noncondensing)
8
to
80%
8
to
80%
8
to
80%
Wet
Bulb
23°C
(73°F)
27°C
(81°F)
29°C
(84°F)
Noise
Emissions
1,
4
Operating
Idle
L
WAd
,
one
7311-D10
L
WAd
,
two
7311-D10
L
WAd
,
four
7311-D10
5.6
bels
5.9
bels
6.2
bels
5.6
bels
5.9
bels
6.2
bels
<L
pA
>
m
,
one
7311-D10
<L
pA
>
m
,
two
7311-D10
<L
pA
>
m
,
four
7311-D10
40
dBA
43
dBA
46
dBA
40
dBA
43
dBA
46
dBA
Install/Air
Flow
:
Maintaining
service
clearance
allows
proper
air
flow.
Service
Clearances
:
See
7014
Series
Model
T00
and
T42
Rack
Installation
and
Service
Guide
,
order
number
SA38-0577
for
T00
or
T42
rack
service
clearances.
1.
See
page
182
for
definitions
of
noise
emissions
positions.
See
noise
emissions
note
4.
2.
Inrush
currents
occur
only
at
initial
application
of
power,
no
inrush
occurs
during
normal
power
off-on
cycle.
3.
The
upper
limit
of
the
dry
bulb
temperature
must
be
derated
1°C
per
137
m
(450
ft.)
above
915
m
(3000
ft.).
4.
The
upper
limit
of
the
wet
bulb
temperature
must
be
derated
1°C
per
274
m
(900
ft.
)
above
305
m
(1000
ft.).
Chapter
1.
Reference
Information
35
Summary of Contents for eserver pSeries 7311 D10
Page 1: ...pSeries 7311 Model D10 and Model D20 Service Guide SA38 0627 01 ERserver...
Page 2: ......
Page 3: ...pSeries 7311 Model D10 and Model D20 Service Guide SA38 0627 01 ERserver...
Page 8: ...vi Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 12: ...x Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 14: ...xii Eserver pSeries 7311 Model D10 and Model D20 Service Guide...
Page 25: ...1 Processor Subsystem 2 I O Subsystem Chapter 1 Reference Information 9...
Page 89: ...Chapter 3 Removal and Replacement Procedures 73...
Page 99: ...2 1 1 Top of Cassette 2 Handle Chapter 3 Removal and Replacement Procedures 83...
Page 179: ...D10 I O Subsystem Parts continued 1 2 3 4 5 6 7 Chapter 4 Parts Information 163...
Page 207: ......