11002620
Explanation:
12V dc pGood input fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002622
Explanation:
Expansion_Comp_pGood_fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002629
Explanation:
1.5V reg_pgood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
1100262B
Explanation:
1.8V reg_pgood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
1100262C
Explanation:
5V reg_pgood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002620 • 1100262C
110
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...