B2005123
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B2005127
Explanation:
Timeout occurred during a main store dump IPL.
Response:
There was not enough memory available for the dump to complete before the timeout occurred. Retry
the main store dump IPL, or else power on the partition normally.
B2005135
Explanation:
A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response:
Look for other errors and resolve them.
B2005137
Explanation:
A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response:
Look for other errors and resolve them.
B2005145
Explanation:
A problem occurred during the startup of a partition. There was an error writing the partition main
storage dump to the partition load source. The main store dump startup will continue.
Response:
Look for other errors and resolve them.
B2005148
Explanation:
A problem occurred during the startup of a partition. An error occurred while doing a main storage
dump that would have caused another main storage dump. The startup will not continue.
Response:
Go to Isolating firmware problems.
B2005149
Explanation:
A problem occurred during the startup of a partition while doing a Firmware Assisted Dump that
would have caused another Firmware Assisted Dump.
Response:
Check for server firmware updates; then, install the updates if available.
B2005123 • B2005149
Chapter 8. Troubleshooting
147
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...