B6000266
Explanation:
Contact was lost with the device indicated in the SRC. The operating system is halted waiting for the
I/O function of a critical resource to return. When the I/O returns this SRC will disappear from the panel and the
O/S will continue running. This problem occurs when the connection to the I/O resource or host is suspended, lost
or there is a problem with I/O in the host.
The O/S cannot notify or call home in this state.
This SRC will continue to be refreshed in the panel periodically in the third and fourth "XX" digits (A6XX0266 or
B6XX0266) while the O/S is in this state.
Service action / serviceable event : YES
Called home automatically: Conditional from the management console.
v
If this LPAR was defined from the managent console with the option for calling home crashes and hangs then the
management console will call this problem home.
v
Otherwise this problem will not be called home.
Problem determination:
Do not power off the LPAR. Look for and repair problems in the I/O host.
B6xx0255
Explanation:
Contact was lost with the device indicated in the SRC. The operating system is halted waiting for the
I/O function of a critical resource to return. When the I/O returns this SRC will disappear from the panel and the
O/S will continue running. This problem occurs when the connection to the I/O resource or host is suspended, lost
or there is a problem with I/O in the host.
The O/S cannot notify or call home in this state.
Service action / serviceable event : YES
Called home automatically: Conditional from the management console.
v
If this LPAR was defined from the managent console with the option for calling home crashes and hangs then the
management console will call this problem home.
v
Otherwise this problem will not be called home.
Problem determination:
Do not power off the LPAR. Look for and repair problems in the I/O host.
B6xx0266
Explanation:
Contact was lost with the device indicated in the SRC. The operating system is halted waiting for the
I/O function of a critical resource to return. When the I/O returns this SRC will disappear from the panel and the
O/S will continue running. This problem occurs when the connection to the I/O resource or host is suspended, lost
or there is a problem with I/O in the host.
The O/S cannot notify or call home in this state.
This SRC will continue to be refreshed in the panel periodically in the third and fourth "XX" digits (A6XX0266 or
B6XX0266) while the O/S is in this state.
Service action / serviceable event : YES
Called home automatically: Conditional from the management console.
v
If this LPAR was defined from the managent console with the option for calling home crashes and hangs then the
management console will call this problem home.
v
Otherwise this problem will not be called home.
Problem determination:
Do not power off the LPAR. Look for and repair problems in the I/O host.
B6000266 • B6xx0266
Chapter 8. Troubleshooting
159
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...