268B-112
Explanation:
The diagnostic test failed. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
268B-114
Explanation:
An unrecoverable hardware error. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
268B-116
Explanation:
A protocol error.
1.
Make sure that the firmware of the FRUs shown and the parent adapter, are compatible with the diagnostic and
application software levels.
2.
If you do not find a problem, call your operating-system support person.
Response:
Failing Item:
v
268B-117
Explanation:
A write-protect error occurred. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
268B-118
Explanation:
A SCSI command time-out occurred. Replace the 300 GB SFF SAS Hard Disk Drive. Run diagnostics
again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v
v
268B-112 • 268B-118
Chapter 8. Troubleshooting
343
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...