3.
Retry the operation
4000008a-00000000
Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to
start.
Explanation:
Restoration of the configuration of the specified management controller from a file by the specified
user has failed to start.
May also be shown as 4000008a00000000 or 0x4000008a00000000
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
IMM and
ID:
0138
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to
reset the IMM.
2.
After 45 seconds, reconnect the server to the power source and turn on the server.
3.
Retry the operation
4000008b-00000000
One or more of the Storage Management IP addresses has changed.
Explanation:
This message is for the use case where an IP address for the Storage Management has changed
May also be shown as 4000008b00000000 or 0x4000008b00000000
Severity:
Info
Alert Category:
System - IMM Network event
Serviceable:
No
CIM Information: Prefix:
IMM and
ID:
0139
SNMP Trap ID:
37
Automatically notify Support:
No
User response:
Information only; no action is required.
80010202-0701ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation:
A voltage has dropped below its specified threshold.
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity:
Error
Alert Category:
Critical - Voltage
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0480
SNMP Trap ID:
1
Automatically notify Support:
Yes
User response:
Use one of the following procedures:
v
If the specified sensor is Planar 3.3V or Planar 5V, replace the system board.
v
If the specified sensor is Planar 12V, check the Chassis Management Module or Flex System Manager event log for
power-supply-related issues, and resolve those issues. If the problem remains, replace the system board.
4000008a-00000000 • 80010202-0701ffff
108
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...