806f0107-0304ffff
An over-temperature condition has been detected on [ProcessorElementName].
Explanation:
The temperature of microprocessor 4 has exceeded the critical level, causing a hard shutdown of the
compute node.
May also be shown as 806f01070304ffff or 0x806f01070304ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0036
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps until the problem is solved:
1.
Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
4.
Make sure that the microprocessor heat sink is securely installed.
5.
Make sure that the microprocessor heat sink is installed correctly and the thermal material is correctly applied.
6.
Replace microprocessor 4.
806f0107-2584ffff
An over-temperature condition has been detected on [ProcessorElementName].
Explanation:
The temperature of the specified microprocessor has risen above its specified threshold.
May also be shown as 806f01072584ffff or 0x806f01072584ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0036
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps until the problem is solved:
1.
Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
4.
Make sure that the heat sink for the specified microprocessor is securely installed.
5.
Make sure that the heat sink for the specified microprocessor is installed correctly and the thermal material is
correctly applied.
6.
Replace the specified microprocessor.
806f0109-0701ffff
system board 1 has been Power Cycled.
Explanation:
The compute node has been powered off and powered on.
May also be shown as 806f01090701ffff or 0x806f01090701ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
806f0107-0304ffff • 806f0109-0701ffff
142
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...