the compute node. In addition, the fault LED on the chassis system LED
panel is lit. You can check the CMM event log to determine the source of
the condition. For more information, see “Viewing event logs without
restarting the compute node” on page 64“Viewing event logs without
restarting the compute node” on page 56. See “Light path diagnostics
LEDs” on page 59 for more information about the LEDs on the compute
node.
The fault LED turns off only after the error is corrected.
Note:
When the fault LED turns off, you should also clear the IMM event
log. Use the Setup utility to clear the IMM event log.
Check log LED
When this yellow LED is lit, it indicates that a condition that causes an
event to be logged in the event log has occurred. To view the IMM2 event
log see “IMM event log” on page 63
The check log LED can be turned off through the CMM
led
command, the
CMM web interface, or IBM Flex System Manager management software
(if installed).
v
For more information about the CMM
led
command, see the "IBM Flex
v
From the CMM web interface, select
Compute Nodes
from the
Chassis
Management
menu. For more information, see the "IBM Flex System
Chassis Management Module: User's Guide" athttp://
publib.boulder.ibm.com/infocenter/flexsys/information/topic/
com.ibm.acc.cmm.doc/cmm_user_guide.html. All fields and options are
described in the CMM web interface online help.
v
For more information about IBM Flex System Manager management
software, see the "IBM Flex System Manager Software: Installation and
Service Guide" at http://ralfss21.raleigh.ibm.com:8099/help/topic/
com.ibm.acc.8731.doc/product_page.html.
Notes:
1.
Alternatively, you can use the
CMM_INDICATES_ITE_ERROR_N
command to light the check log LED. See the "IBM Flex System Chassis
Management Module: Command-Line Interface Reference Guide" at
http://ralfss21.raleigh.ibm.com:8099/help/topic/
com.ibm.acc.cmm.doc/cmm_cli_guide.html for more information.
2.
You can check the CMM event log to determine the source of the
condition. For more information, see “Viewing event logs without
restarting the compute node” on page 64.
Identify LED
The system administrator can remotely light this blue LED to aid in
visually locating the compute node. When this LED is lit, the identify LED
on the IBM Flex System chassis is also lit. The identify LED can be lit and
turned off through the CMM
led
command, the CMM web interface, or
IBM Flex System Manager management software (if installed).
v
For more information about the CMM
led
command, see the "IBM Flex
Chapter 1. Introduction
11
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...