[W.3868001] BOFM: Reset loop avoided - Multiple resets not allowed.
Explanation:
BOFM: Reset loop avoided - Multiple resets not allowed
Severity:
Warning
User response:
Complete the following steps:
1.
Update all firmware (including adapter firmware) to the latest levels.
2.
If problem persists escalate to the next level of support.
W.3868002
[W.3868002] BOFM: Error communicating with the IMM - BOFM may not be deployed correctly.
Explanation:
BOFM: Error communicating with the IMM - BOFM may not be deployed correctly
Severity:
Warning
User response:
Complete the following steps:
1.
Update all firmware (including adapter firmware) to the latest levels.
2.
If problem persists escalate to the next level of support.
W.3938002
[W.3938002] A boot configuration error has been detected.
Explanation:
Boot Configuration Error
Severity:
Warning
User response:
Complete the following steps:
1.
F1 Setup -> Save Settings
2.
Retry OOB config update
W.50001
[W.50001] A DIMM has been disabled due to an error detected during POST.
Explanation:
DIMM Disabled
Severity:
Warning
User response:
Complete the following steps:
1.
If the DIMM was disabled because of a memory fault, follow the procedure for that event.
2.
If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
3.
If problem persists, Power cycle the node from management console.
4.
Reset IMM to default settings.
5.
Reset UEFI to default settings.
6.
Reflash IMM and UEFI firmware.
7.
(Trained Service technician only) Replace system board.
W.58001
[W.58001] The PFA Threshold limit (correctable error logging limit) has been exceeded on DIMM
number % at address %. MC5 Status contains % and MC5 Misc contains %.
Explanation:
DIMM PFA Threshold Exceeded
Severity:
Warning
User response:
Complete the following steps:
1.
If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated
and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of
these conditions is found, correct and retry with the same DIMM. (Note: Event Log may contain a recent 00580A4
event denoting detected change in DIMM population that could be related to this problem.)
2.
Check IBM support site for an applicable firmware update that applies to this memory error. The release notes
will list the known problems the update addresses.
W.3868001 • W.58001
Chapter 6. Troubleshooting
455
Summary of Contents for Flex System x440 Compute Node
Page 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Page 583: ......
Page 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...