Table
3-1 (Page 18 of 38). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00071
VPD data corrupted for CPU in
processor card connector #1
Replace the CPU card in processor card
connector #1.
2BA00073
VPD data corrupted for CPU in
processor card connector #2
Replace the CPU card in processor card
connector #2.
2BA00100
Service processor firmware recovery
information could not be written to
diskette
1. Check diskette media write protect
tab.
2. Replace the diskette drive.
2BA00101
Service processor is not installed,
update cancelled
1. Install the service processor (Model
H50 only).
2. Retry operation.
2BA00102
No service processor update
diskette in drive
Insert the diskette.
2BA00103
Service processor firmware update
file is corrupted, update cancelled
1. Obtain new service processor
firmware diskette.
2. Retry operation.
2BA00104
Service processor firmware update
file is the same level as the service
processor firmware, update can-
celled
1. Obtain new level of service processor
firmware.
2. Retry operation.
2BA00200
Service processor firmware update
error occurred, update not com-
pleted
Error occurred during service
processor flash write operation.
Service processor firmware update error
recovery procedure:
1. Turn the system Off.
2. Unplug power cable and then plug
power cable back in.
3. Turn the system On.
4. Retry operation. If problem persists:
For Model H50: Replace Service
Processor.
For Model H70: Replace I/O board.
2BA00201
Service processor firmware update
error occurred, update not com-
pleted
Error occurred while reading service
processor CRC.
See error code 2BA00200 for recovery
procedure.
2BA00202
Service processor firmware update
error occurred, update not com-
pleted
Error occurred while verifying
service processor CRC.
See error code 2BA00200 for recovery
procedure.
Chapter 3. Error Code to FRU Index
3-19
Summary of Contents for H SERIES RS/6000
Page 1: ...RS 6000 Enterprise Server Model H Series IBM Installation and Service Guide SA38 0547 01...
Page 14: ...xiv RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 34: ...1 18 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 106: ...2 72 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 178: ...3 72 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 262: ...7 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 279: ...Chapter 7 Removal and Replacement Procedures 7 31...
Page 315: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 328: ...8 14 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 340: ...A 12 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 401: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix E Modem Configurations E 21...
Page 408: ...E 28 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 412: ...F 4 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 419: ...Index X 7...
Page 420: ...X 8 RS 6000 Enterprise Server Model H Series Installation and Service Guide...
Page 423: ......