170
IBM 9077 SP Switch Router: Get Connected to the SP Switch
5. Have
smitty
carry out its work, exit
smitty
and then run
smitty mkatmpvc
:
In the optional
PVC Description
field, do not use blanks or underscores. In
the
VPI:VCI
field, use the numbers you get from the PVC statement in the
/etc/gratm.conf file on the GRF 1600. For your convenience, the relevant
line is shown here again:
PVC ga0180 0/134 proto=ip traffic_shape=high_speed_high_quality
Note:
Be very careful about the different naming conventions on the GRF
and on AIX! Whereas the numbers are separated by a slash (/) in
/etc/gratm.conf, you must use a colon (:) to separate them in SMIT!
Because we give the
VPI:VCI
numbers of the GRF ATM port and leave the
field
Automatically Discover Destination IP Address
on its
yes
default,
there is no need to fill in the
Destination IP Address
.
After
smitty
is done, you should be able to
ping
the at0 interface on the
F50:
You should also be able to ping the ga0180 port of the GRF:
Add a PVC for IP over an ATM Network
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
PVC Description (Optional) [F50toGRF]
* VPI:VCI [0:134]
Network Interface [at0]
Destination IP Address []
Automatically Discover Destination IP Address yes +
LLC Encapsulation yes +
(0)f50:/ 14$ ping 10.1.2.3
PING 10.1.2.3: (10.1.2.3): 56 data bytes
64 bytes from 10.1.2.3: icmp_seq=0 ttl=255 time=13 ms
64 bytes from 10.1.2.3: icmp_seq=1 ttl=255 time=0 ms
64 bytes from 10.1.2.3: icmp_seq=3 ttl=255 time=0 ms
^C
----10.1.2.3 PING Statistics----
3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0/3/13 ms
(0)f50:/ 15$
Summary of Contents for IBM 9077
Page 2: ......
Page 18: ...xvi IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 19: ... Copyright IBM Corp 1998 1 Part 1 Introducing and Installing the GRF ...
Page 20: ...2 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 86: ...68 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 122: ...Installation and Configuration 104 ...
Page 174: ...156 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 220: ...202 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 278: ...260 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 322: ...304 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 326: ...308 IBM 9077 SP Switch Router Get Connected to the SP Switch ...
Page 332: ...314 IBM 9077 SP Switch Router Get Connected to the SP Switch ...