15.
Press Esc to return to the
Configuration Settings
menu.
Configure iSCSI HBA for manual addressing
Learn how to use the configuration utility to prepare the iSCSI HBA to use manual addressing. Use the
procedure in this section to accomplish this task.
Note:
These procedures start from the
Configuration Settings
menu if you need to restore this menu see,
“Start the iSCSI HBA configuration utility” on page 17 then return to this procedure.
To configure the selected iSCSI HBA port for manual addressing, perform the following steps. The xSeries
or blade system iSCSI HBA settings are configured first starting from the
Configuration Settings
menu.
1.
Highlight
Host Adapter settings
using the up or down arrow keys and press Enter.
2.
Highlight
LUNs per Target
using the up or down arrow keys and press Enter. Use the arrow keys to
select the value
64
and press Enter. This option is not available in adapter version 406x.
3.
Highlight
Initiator IP Address via DHCP
using the up or down arrow keys and press Enter until
the value shows
NO
.
Important:
In adapter version 406x select only the
IPv4
options for the following steps.
4.
Highlight
Initiator IP address
using the up or down arrow keys and press Enter. Type the Integrated
Server HBA iSCSI Initiator IP address from the
iSCSI Network Planning Worksheets
item CQ3 and
press Enter.
5.
Highlight
Subnet mask
using the up or down arrow keys and press Enter to select. Type the iSCSI
Initiator subnet mask from the
iSCSI Network Planning Worksheets
item CQ4 and press Enter.
6.
Highlight
Gateway IP Address
using the up or down arrow keys and press Enter to select. Type the
iSCSI Initiator gateway IP address from the
iSCSI Network Planning Worksheets
item CQ5 and press
Enter.
7.
Highlight
Initiator iSCSI Name
using the up or down arrow keys and press Enter to select. Type the
name (
iqn.1924-02.com.ibm:...
) from the
iSCSI Network Planning Worksheets
item CQ6 and press
Enter.
8.
Clear the
Initiator Chap Name
and
Initiator Chap Secret
fields. Highlight each field and using the
up or down arrow keys, press Enter, type in a single space and press Enter to clear each field.
Note:
Initiator Challenge Handshake Authentication Protocol (CHAP) is not supported, so these
fields must be blank.
9.
Press Esc to return to the
Configuration Settings
menu.
10.
Highlight
iSCSI Boot Settings
using the up or down arrow keys and press Enter to display the
iSCSI Boot Settings menu.
11.
Highlight
Adapter Boot Mode
using the up or down arrow keys and press Enter.
12.
Highlight
Manual
using the up or down arrow keys and press Enter.
13.
Highlight
Primary Boot Device Settings
using the up or down arrow keys and press Enter.
14.
Highlight
Target IP
using the up or down arrow keys and press Enter to select. Type the iSeries
®
iSCSI HBA iSCSI IP address from the
iSCSI Network Planning Worksheets
item CQ10 and press Enter.
15.
Highlight
iSCSI Name
using the up or down arrow keys and press Enter. i5/OS will generate the
IQN for the target side and it must be matched here. Type the iSCSI name from the
iSCSI Network
Planning Worksheets
item CQ11 and press Enter.
16.
Highlight
Security Settings
using the up or down arrow keys and press Enter to display the
Primary Boot Security Settings
menu.
17.
Highlight
Chap
using the up or down arrow keys and press Enter to change the value to
Enabled
or
Disabled
, based on whether or not CHAP will be used. Refer to the
iSCSI Network Planning
Worksheets
item CQ12 for this information. Skip to step 21 if CHAP has been disabled.
Configure iSCSI HBA
19
Summary of Contents for iSCSI Host Bus Adapter
Page 1: ...System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 2: ......
Page 3: ...System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 12: ...x System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 28: ...16 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 34: ...22 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 36: ...24 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 50: ...38 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 60: ...48 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 61: ......
Page 62: ... Printed in USA ...