Insert the media containing the iSCSI HBA update in the drive and turn on the blade server power.
Refer to the blade server documentation to complete this step.
3.
Wait for the server to complete POST. It should then access the drive with the update media loaded
and proceed to boot off the media. It will take several minutes to complete this.
4.
The blade server should boot to the update utility, which will present a screen informing about the
contents of the update. Type
y
to continue with the update.
5.
When the update completes, turn off the server’s power. Refer to blade server documentation to
complete this step.
Repeat steps 1-5 for any other blade servers to be updated.
Set the blade start options
Configure the start options before continuing with the installation. Use the procedure in this section to
disable the Pre-Boot Execution Environment (PXE) option for all integrated Ethernet ports, turn off the
boot fail counter, and turn off virus detection.
1.
Turn on the blade server. Refer to the server documentation to complete this step.
2.
Press F1 when prompted, after the IBM eServer logo appears on the display.
3.
Highlight
Start Options
using the up or down arrow keys and press Enter.
4.
Highlight
Planar Ethernet PXE/DHCP
using the up or down arrow keys. Use the right or left arrow
keys to change the value to
Disabled
.
5.
Highlight
Boot Fail Count
using the up or down arrow keys and use the right or left arrow keys to
change the value to
Disabled
.
6.
Highlight
Virus Detection
using the up and down arrow keys and use the right or left arrow keys to
change the value to
Disabled
.
7.
Press the Esc key to return to the main setup menu.
Complete the blade server configuration
Save all the configuration settings and exit the setup utility to complete the server configuration. Use the
procedure in this section to accomplish this task.
1.
From the main setup menu, highlight
Save Settings
using the up or down arrow keys and press
Enter.
2.
From the
Save Settings
window, press Enter to save.
3.
From the main setup menu, press Esc to exit setup.
4.
From the
Exit Setup
window, use the up or down arrow keys to highlight
Yes, exit the Setup Utility
and press Enter.
5.
The server power can now be turned off. Refer to blade server documentation to complete this step.
Prepare your system
15
Summary of Contents for iSCSI Host Bus Adapter
Page 1: ...System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 2: ......
Page 3: ...System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 12: ...x System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 28: ...16 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 34: ...22 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 36: ...24 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 50: ...38 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 60: ...48 System i and System p iSCSI Host Bus Adapter for IBM BladeCenter System x or xSeries ...
Page 61: ......
Page 62: ... Printed in USA ...