1.
Select
Manual
mode
and
perform
an
IPL
to
DST
(see
in
the
iSeries
(TM)
Service
Functions
information).
Does
the
Disk
Configuration
Error
Report
display
appear?
v
Yes
:
Does
a
″
Load
source
failure
″
message
appear
in
the
list?
–
Yes
:
Continue
with
the
next
step.
–
No
:
The
system
is
now
using
the
correct
load-source.
This
ends
the
procedure.
v
No
:
The
system
is
now
using
the
correct
load-source.
This
ends
the
procedure.
2.
Select
option
5
,
press
F11
,
and
then
press
Enter
to
display
details.
The
load-source
type,
model,
and
serial
number
information
that
the
system
needs
is
displayed
on
the
console.
Is
the
load-source
disk
unit
(displayed
on
the
console)
attached
to
an
MSIOP
that
cannot
be
used
for
a
load-source?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
load-source
disk
unit
is
missing.
Go
to
step
1
(See
page
for
cause
code
0002.
3.
Is
the
system
configured
for
remote
load-source
protection?
v
No
:
Move
the
load-source
disk
unit
to
the
load-source
MSIOP.
This
ends
the
procedure.
v
Yes
:
Go
to
001C:
The
disk
units
that
are
needed
to
update
the
system
configuration
are
missing.
Perform
an
IPL
by
doing
the
following:
1.
Select
Manual
mode
on
the
control
panel.
2.
Perform
an
IPL
(see
in
the
iSeries
(TM)
Service
Functions
information)
to
determine
the
cause
of
the
problem.
This
ends
the
procedure.
001D:
1.
Is
the
Disk
Configuration
Attention
Report,
or
the
Disk
Configuration
Warning
Report
displayed?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Ask
your
next
level
of
support
for
assistance.
This
ends
the
procedure.
2.
On
the
Bad
Load
Source
Configuration
message
line,
select
5
,
and
press
Enter
to
rebuild
the
load-source
configuration
information.
If
there
are
other
types
of
warnings,
select
option
5
on
the
warnings,
and
correct
the
problem.
This
ends
the
procedure.
001E:
The
load-source
data
must
be
restored.
Go
to
This
ends
the
procedure.
001F:
Licensed
Internal
Code
was
installed
on
the
wrong
disk
unit
of
the
load-source
mirrored
pair.
The
system
performed
an
IPL
on
a
load
source
that
may
not
contain
the
same
level
of
Licensed
Internal
Code
that
was
installed
on
the
other
load
source.
The
type,
model,
and
address
of
the
active
device
are
displayed
in
words
4-7
of
the
SRC.
1.
Choose
from
the
following
options:
Analyze
hardware
problems
131