5.
Search
the
entries
on
the
Log
Analysis
Report
display
for
system
reference
codes
associated
with
the
missing
disk
units.
6.
Go
to
and
use
the
SRC
information
to
correct
the
problem.
This
ends
the
procedure.
0024:
The
system
type
or
system
unique
ID
needs
to
be
entered.
1.
Select
Manual
mode
and
perform
an
IPL
to
DST
(see
in
the
iSeries
(TM)
Service
Functions
information).
2.
When
prompted,
enter
the
correct
system
type
or
system
unique
ID.
This
ends
the
procedure.
0025:
Hardware
Resource
Information
Persistence
disabled.
1.
Select
Manual
mode
and
perform
an
IPL
to
DST
(see
in
the
iSeries
(TM)
Service
Functions
information).
2.
Contact
your
next
level
of
support
for
instructions
on
how
to
enable
the
Hardware
Resource
Information
Persistence
function.
This
ends
the
procedure.
0026:
A
disk
unit
is
incorrectly
configured
for
an
LPAR
system.
1.
Select
Manual
mode
and
perform
an
IPL
to
DST
(see
in
the
iSeries
(TM)
Service
Functions
information).
2.
On
the
Service
Tools
display,
select
Start
a
Service
Tool
—>
Product
activity
log
—>
Analyze
log
—>.
3.
On
the
Select
Subsystem
Data
display,
select
the
option
to
view
All
Logs.
Note:
You
can
change
the
From:
and
To:
Dates
and
Times
from
the
24-hour
default
if
the
time
that
the
customer
reported
having
the
problem
was
more
than
24
hours
ago.
4.
Use
the
defaults
on
the
Select
Analysis
Report
Options
display
by
pressing
Enter
.
5.
Search
the
entries
on
the
Log
Analysis
Report
display
for
system
reference
codes
(B6xx
53xx)
that
are
associated
with
the
error.
6.
Go
to
and
use
the
SRC
information
to
correct
the
problem.
This
ends
the
procedure.
0031:
A
problem
was
detected
with
the
installation
of
Licensed
Internal
Code
service
displays.
The
cause
may
be
defective
media,
the
installation
media
being
removed
too
early,
a
device
problem
or
a
Licensed
Internal
Code
problem.
v
Ask
your
next
level
of
support
for
assistance.
Characters
13-16
of
the
top
16
character
line
of
function
12
(4
rightmost
characters
of
word
3)
contain
information
regarding
the
install
error.
v
For
more
information
about
the
install
error,
see
the
″
LIC
Install
Debug
Information
″
chapter
in
the
iSeries
(TM)
Licensed
Internal
Code
Diagnostic
Aids
-
Volume
1
.
v
If
the
customer
does
not
require
the
service
displays
to
be
in
the
national
language,
you
may
be
able
to
continue
by
performing
another
system
IPL.
This
ends
the
procedure.
0033:
System
model
not
supported.
This
model
of
hardware
does
not
support
the
System
Licensed
Internal
Code
version
and
release
that
is
being
used.
Use
a
supported
version
and
release
of
the
System
Licensed
Internal
Code.
This
ends
the
procedure.
0034:
Insufficient
main
storage
capacity.
Analyze
hardware
problems
133