v
No
:
A
different
SRC
or
reference
code
occurred.
Use
the
new
SRC
or
reference
code
to
correct
the
problem
(see
This
ends
the
procedure.
31.
Are
characters
13-16
of
the
bottom
16
character
line
of
function
13
(4
rightmost
characters
of
word
9)
on
the
Problem
Summary
Form
you
filled
out
in
step
29
(See
page
equal
to
0000?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Return
to
Analyze
the
problem
using
the
data
in
characters
9-16
of
the
bottom
16
character
line
of
function
13
(word
9)
on
the
Problem
Summary
Form
in
place
of
the
data
in
word
1,
which
originally
sent
you
to
this
procedure.
This
ends
the
procedure.
32.
Go
to
the
analyzing
problems
procedures
in
the
service
information
for
the
specific
disk
unit
to
analyze
the
status
of
the
failing
unit.
Then
return
here
and
answer
the
following
question.
Did
the
service
information
for
the
specific
disk
unit
correct
the
problem?
v
No
:
Continue
with
the
next
step.
v
Yes
:
This
ends
the
procedure.
33.
A
manual
reset
of
the
IOP
may
clear
the
attention
SRC.
Perform
the
steps
in
the
following
table:
Primary
partition
steps
Secondary
partition
steps
1.
Select
Manual
mode
on
the
control
panel.
2.
Select
Function
25
and
press
Enter
.
3.
Select
Function
26
and
press
Enter
.
4.
Select
Function
67
and
press
Enter
to
reset
the
IOP.
5.
Select
Function
25
and
press
Enter
to
disable
the
service
functions
on
the
control
panel.
1.
From
the
SST/DST
screen
select
Work
With
Partitions
—>
Work
With
Partition
Status
.
2.
Select
Function
23
More
Options.
3.
Select
option
59
for
the
logical
partition
that
you
are
working
in.
4.
Select
the
IOP
for
debug.
5.
Select
Reset
I/O
Processor
.
6.
Return
to
the
Partition
Status
display.
Does
an
SRC
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
This
ends
the
procedure.
34.
Force
a
dump
of
main
storage,
then
perform
an
IPL
by
doing
the
following:
a.
Select
Manual
mode
on
the
control
panel.
b.
Select
function
22
(Main
Storage
Dump)
on
the
control
panel.
c.
Press
Enter
to
force
a
dump
of
main
storage
to
the
load-source
disk
unit.
d.
When
SRC
A100
300x
occurs,
the
dump
is
complete.
e.
Perform
an
IPL
to
DST
(see
in
the
iSeries
(TM)
Service
Functions
information).
Does
a
different
SRC
occur,
or
does
a
display
appear
on
the
console
showing
reference
codes.
v
No
:
Continue
with
the
next
step.
v
Yes
:
Use
the
new
SRC
or
the
URC
displayed
on
the
console
and
go
to
to
correct
the
problem.
This
ends
the
procedure.
35.
Does
the
same
SRC
occur?
v
No
:
The
problem
is
intermittent.
a.
the
system
product
activity
log
for
the
magnetic
storage
subsystem
and
the
LIC
LOGs
with
a
major
code
of
1000.
Analyze
hardware
problems
143