v
The
storage
I/O
adapter
is
connected
to
a
non-operational
auxiliary
cache
I/O
adapter
Perform
the
following:
1.
Ensure
that
the
SCSI
cable
on
the
last
port
of
the
storage
I/O
adapter
is
connected
to
the
auxiliary
cache
I/O
adapter.
Do
the
following:
a.
Use
the
location
of
the
storage
I/O
adapter
displayed
in
the
Service
Action
Log.
If
the
Service
Action
Log
does
not
have
a
location,
determine
the
address
of
the
storage
I/O
adapter.
See
b.
Determine
the
location
of
the
storage
I/O
adapter.
See
for
the
model
you
are
working
on.
c.
Ensure
that
the
SCSI
cable
on
the
last
port
of
the
storage
I/O
adapter
is
properly
connected
to
an
auxiliary
cache
I/O
adapter.
d.
Ensure
that
the
slot
power
indicator
is
lit
for
the
auxiliary
cache
I/O
adapter.
If
it
is
not,
use
concurrent
maintenance
to
power
on
the
slot.
2.
Ensure
that
the
auxiliary
cache
I/O
adapter
is
supported
for
the
storage
I/O
adapter
to
which
it
is
connected.
See
installation
instructions
for
information
about
which
adapters
are
compatible.
3.
Replace
the
SCSI
cable
on
the
last
port
of
the
storage
I/O
adapter
that
connects
to
the
auxiliary
cache
I/O
adapter.
See
for
cable
part
number
information.
If
this
does
not
fix
the
problem,
replace
the
auxiliary
cache
I/O
adapter.
This
ends
the
procedure.
SDIOP-PIP41:
One
of
the
following
situations
has
occurred:
v
The
auxiliary
cache
I/O
adapter
is
not
connected
to
a
storage
I/O
adapter
v
The
auxiliary
cache
I/O
adapter
is
connected
to
an
incompatible
storage
I/O
adapter
v
The
auxiliary
cache
I/O
adapter
is
connected
to
a
non-operational
storage
I/O
adapter
Perform
the
following:
1.
Ensure
that
the
SCSI
cable
of
the
auxiliary
cache
I/O
adapter
is
connected
to
the
last
port
of
the
storage
I/O
adapter.
Do
the
following:
a.
Use
the
location
of
the
storage
I/O
adapter
displayed
in
the
Service
Action
Log.
If
the
Service
Action
Log
does
not
have
a
location,
determine
the
address
of
the
auxiliary
cache
I/O
adapter.
See
b.
Determine
the
location
of
the
auxiliary
cache
I/O
adapter.
See
for
the
model
you
are
working
on.
c.
Ensure
that
the
SCSI
cable
of
the
auxiliary
cache
I/O
adapter
is
properly
connected
to
the
last
port
of
the
storage
I/O
adapter.
d.
Ensure
that
the
slot
power
indicator
is
lit
for
the
storage
I/O
adapter.
If
it
is
not,
use
concurrent
maintenance
to
power
on
the
slot.
2.
Ensure
that
the
auxiliary
cache
I/O
adapter
is
supported
for
the
storage
I/O
adapter
to
which
it
is
connected.
See
installation
instructions
for
information
about
which
adapters
are
compatible.
3.
Replace
the
SCSI
cable
that
connects
the
auxiliary
cache
I/O
adapter
to
the
storage
I/O
adapter.
See
for
cable
part
number
information.
If
this
does
not
fix
the
problem,
replace
the
storage
I/O
adapter.
This
ends
the
procedure.
Storage
device
I/O
card
FRU
locations:
For
use
by
authorized
service
providers.
Use
the
table
below
to
find
FRU
locations.
If
only
a
type
number
is
listed,
go
to
the
to
determine
the
part
number.
If
the
failing
item
is
an
FI
code,
see
Note:
See
to
help
find
FRUs
that
are
not
in
this
table.
212
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation