Value
for
EEEE
Value
for
AAAAAAAA
Recommended
Service
Action:
2109
BFD10000
Load
source
interface
error.
The
power
control
logic
detected
a
power
fault
associated
with
an
IOP
or
IOA
slot
somewhere
on
Bus
1.
The
power
fault
may
be
caused
by
a
bad
slot
or
by
a
card
plugged
into
that
slot.
First,
isolate
the
problem
to
a
card
or
slot
by
unplugging
all
cards
in
slots
on
Bus
1
other
than
the
load
source
IOP
and
the
first
storage
IOA
and
try
an
IPL.
If
the
problem
persists,
move
the
IOP
or
IOA
to
other
slots.
If
the
problem
goes
away,
replace
the
service
processor.
If
the
problem
persists,
replace
either
the
IOP
or
IOA
and
retry
the
IPL.
If
the
problem
has
not
been
isolated
yet,
plug
each
card
back
in
one
at
a
time
and
retry
the
IPL
until
the
problem
returns.
Try
an
IPL
with
that
card
in
another
slot.
If
the
problem
returns,
replace
the
card.
Otherwise,
replace
the
service
processor.
210E
********
Load
source
internal
error.
The
load
source
IOP
encountered
an
error
while
communicating
with
the
load
source
device.
The
device
unit
address
is
DDDDDDDD
(word
8).
Use
symbolic
FRU
to
fix
the
problem.
2111
********
Load
source
device
became
non-operational.
The
load
source
IOA
encountered
an
error
while
communicating
with
the
load
source
device.
The
device
unit
address
is
in
DDDDDDDD
(word
8).
Use
symbolic
FRU
to
fix
the
problem.
Analyze
hardware
problems
217