212A
********
Load
source
device
not
responding.
The
load
source
device
did
not
respond
to
the
first
storage
IOA
when
queried.
The
load
source
device
may
not
be
powered
on
or
connected
correctly.
Check
the
cabling
for
the
load
source
device,
or
replace
the
load
source
device.
Note
that
the
DSA
and
load
source
address
in
IIIIIIII
(word
7)
and
DDDDDDDD
(word
8)
of
the
SRC
reflect
only
the
device
address
searched,
which
may
normally
not
have
a
device
attached.
However,
all
valid
load
source
addresses
were
searched
before
the
SRC
was
displayed.
If
this
is
a
D
mode
IPL
and
a
device
is
present
but
with
no
media
installed,
this
SRC
could
mask
the
expected
4607
refcode
and
2127
extended
refcode.
Make
sure
the
alternate
device
has
media
installed
before
trying
anything
else.
212D
********
Bad
error
log
data
format.
The
load
source
IOP
encountered
an
error
and
built
an
error
log
entry.
The
service
processor
retrieved
the
error
log
data
but
it
was
in
an
incorrect
format.
Replace
the
load
source
IOP.
214x
********
Load
source
IOP
time
out.
The
load
source
IOP
did
not
respond
in
time
to
a
command
from
the
service
processor.
Replace
the
load
source
IOP.
2150
********
Load
source
IOA
found.
The
IOP
at
the
DSA
in
IIIIIIII
(word
7)
did
not
find
a
storage
IOA
on
Bus
1.
Reseat
or
replace
the
storage
IOA.
Analyze
hardware
problems
219