Value
for
EEEE
Value
for
AAAAAAAA
Recommended
Service
Action:
35AE
********
Load
source
device
not
found
during
main
storage
dump.
The
service
processor
is
directed
to
use
the
load
source
device
during
main
storage
dump,
but
no
load
source
is
found
at
the
device
address
being
used,
or
the
device
is
not
accessible
by
the
service
processor.
The
DSA
of
the
load
source
IOP
is
in
IIIIIIII
(word
7).
The
device
unit
address
is
DDDDDDDD
(word
8).
Verify
the
IOP
DSA
and
device
unit
address
are
correct
for
the
location
of
the
load-source
on
this
system.
7.
If
the
problem
is
not
resolved,
go
to
symbolic
FRU
This
ends
the
procedure.
SP-PIP44:
Use
this
procedure
if
you
have
a
B1xx
4682
SRC
detected
on
a
Model
825.
1.
Locate
the
Extended
Reference
Code
in
characters
9
through
12
of
the
top
16
characters
of
Function
12:
12
xxxxxxxxEEEExxxx
xxxxxxxxxxxxxxxx
2.
Use
the
following
table
to
find
the
recommended
service
action.
Table
1.
Recommended
service
action
for
B1xx
4682
SRC
on
a
Model
825
Value
for
EEEE:
Recommended
service
action:
804B
1.
Replace
the
control
panel
(see
symbolic
FRU
2.
Then,
IPL
the
system.
3.
If
the
same
error
occurs
again,
replace
the
backplane
(see
symbolic
FRU
804C
v
If
a
card
is
located
in
position
C09:
1.
Power
off
the
system
and
reseat
the
card.
2.
Then,
IPL
the
system.
3.
If
the
same
error
occurs
again,
replace
the
card
in
C09
(see
4.
Then,
IPL
the
system.
5.
If
the
same
error
occurs
again,
replace
the
backplane
(see
symbolic
FRU
v
If
a
card
is
not
located
in
position
C09,
replace
the
backplane
(see
symbolic
FRU
804D
1.
Replace
the
control
panel
(see
symbolic
FRU
2.
Then,
IPL
the
system.
3.
If
the
same
error
occurs
again,
replace
the
backplane
(see
symbolic
FRU
This
ends
the
procedure.
SP-PIP45:
For
use
by
authorized
service
providers.
This
procedure
is
for
IPL
failures
that
terminate
with
SRC
B1XX4604.
220
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation