Failing
item
code
Description/Action
FI00132
FI00132
indicates
that
one
of
the
IOAs
is
the
failing
item.
Perform
to
isolate
the
failing
IOA.
FI00141
FI00141
indicates
that
the
IOP
for
the
7208
tape
drive
is
the
failing
item.
The
failing
IOP
is
the
type
2621
IOP.
FI00142
This
failing
item
is
in
a
migrated
tower.
See
the
failing
item
table
for
this
failing
item
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
FI00180
This
failing
item
is
in
a
migrated
tower.
See
the
failing
item
table
for
this
failing
item
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
FI00182
For
Models
270
and
820,
FI00182
indicates
that
the
local
optical
link
card
is
the
failing
item.
For
Models
830,
840,
SB2,
and
SB3,
FI00182
indicates
that
the
SPD
optical
bus
driver
is
the
failing
item.
v
If
the
fifth
character
of
word
5
(xxxx
xxxx)
is
1,
5,
9,
or
D—2686
(266
MB/s)
v
If
the
fifth
character
of
word
5
(xxxx
xxxx)
is
3,
7,
B,
or
F—2688
(1062
MB/s)
FI00185
FI00185
indicates
that
the
12-port
ASCII
workstation
attachment
cable
is
the
failing
item.
FI00186
For
the
Model
270
and
820,
FI00186
indicates
that
the
optical
cable
in
the
top
position
(even
bus)
of
the
optical
link
card
is
the
failing
item.
For
the
Model
830,
840,
SB2,
and
SB3,
FI00186
indicates
that
the
optical
cable
in
the
top
position
(lower
number
bus)
of
the
SPD
optical
Bus
Driver
is
the
failing
item.
FI00187
FI00187
indicates
that
the
optical
cable
configuration
is
the
failing
item.
Perform
Bus
PIP1
in
manual
on
the
V5R1
Supplemental
Manuals
web
site
to
correct
the
problem.
FI00189
For
the
Model
270
and
820,
FI00189
indicates
that
the
bus
extension
card
configuration
is
the
failing
item.
For
the
Model
830,
840,
SB2,
and
SB3,
FI00189
indicates
that
the
local
SPD
bus
adapter
configuration
is
the
failing
item.
Perform
Bus
PIP1
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
to
correct
the
problem.
FI00200
FI00200
indicates
that
the
AC
module
or
the
removable
power
cable
is
the
failing
item.
The
following
list
shows
the
possible
failing
AC
modules
(see
for
part
v
System
unit
—
part
SPNLCRD
v
System
unit
expansion
(FC
5070,
5072),
storage
expansion
tower
(FC
5080,
5082)
v
System
unit
expansion
(FC
5071,
5073),
storage
expansion
tower
(FC
5081,
5083)
See
in
the
Plan
for
hardware
and
software
topic
in
Information
Center,
to
determine
the
power
cable
part
number
for
systems
in
your
country
or
region.
This
information
is
also
available
in
the
>Plan
for
hardware
and
software
book
under
the
Power
topic.
Analyze
hardware
problems
253