BATCHGR
For
use
by
authorized
service
providers.
A
battery
power
unit
charger
is
the
failing
item.
When
a
location
and
part
number
are
displayed
on
the
Control
Panel
of
a
system
or
expansion
tower,
replace
that
FRU
first.
Note:
See
before
exchanging
the
the
battery
charger.
Migrated
expansion
tower
remove
and
replace
procedures
are
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
Perform
the
following
to
determine
the
part
number
for
the
failing
unit.
1.
Is
the
SRC
1xxx
4413
displayed?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
symbolic
FRU
If
the
problem
is
not
fixed,
then
return
here.
2.
Exchange
the
battery
power
unit
charger.
Use
the
model
and
feature
code
in
the
table
below
Table
1.
Charger
part
number
Model
or
feature
code
Charger
part
number
840,
SB3
See
FC
5065,
FC
5066,
5074,
FC
5079,
FC
5094,
FC
9074,
FC
9079,
FC
9094
See
.
FC
5071,
FC
5073,
FC
5081,
FC
5083
Replace
the
failing
charger
(see
):
v
Internal
battery
power
unit
1
or
2
charger
v
External
battery
power
unit
2
charger
FC
9309
21F9380
This
ends
the
procedure.
BATRY
For
use
by
authorized
service
providers.
The
battery
may
be
the
failing
item.
Follow
the
instructions
for
the
model
you
are
working
on:
v
Models
270
and
820,
830,
840,
SB2,
and
SB3
(See
page
v
Models
800,
810,
825,
870,
and
890
(See
page
Instructions
for
Models
270,
820,
830,
840,
SB2,
and
SB3
When
there
is
a
location
and
part
number
displayed
on
the
Control
Panel
of
the
system
or
expansion
tower,
then
you
are
to
replace
that
FRU
first.
Note:
See
before
exchanging
the
battery.
Migrated
expansion
tower
remove
and
replace
procedures
are
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
Perform
the
following
to
determine
the
part
number
for
the
failing
unit.
1.
Choose
from
the
following:
Analyze
hardware
problems
285