1.
Is
the
SRC
1xxx
8430,
8431,
8440,
or
8441?
v
Yes
:
Go
to
step
7
(See
page
v
No
:
Continue
with
the
next
step.
2.
Does
the
SRC
1xxx
840D,
840E
or
840F
appear
on
the
panel?
v
No
:
Go
to
the
v
Yes
:
Continue
with
the
next
step.
3.
Is
the
SRC
for
a
xSeries
Server
Unit?
v
Yes
:
Exchange
the
Integrated
xSeries
Adapter
(IXA)
(see
).
v
No
:
Continue
with
the
next
step.
4.
Perform
the
following
to
display
the
Configuration
ID:
Note:
The
system
or
frame
that
will
display
the
ID
MUST
be
powered
down
with
ac
applied.
If
you
are
working
on
a
Model
800
or
810
with
an
FC
7116
expansion
unit,
verify
that
both
the
ac
line
cord
for
the
system
and
the
ac
line
cord
for
the
expansion
unit
are
plugged
in.
a.
Select
Function
07
on
the
system
control
panel
and
press
Enter
.
(07**
will
be
displayed)
b.
Use
the
arrow
keys
to
increment
/
decrement
to
subfunction
A8
.
(07A8
will
be
displayed).
Press
Enter
.
(07A8
00
will
be
displayed)
c.
Use
the
arrow
keys
to
increment
/
decrement
to
the
frame
address
of
the
box
you
want
to
check
(usually
02,
03,
...
for
the
towers,
01
for
system
unit
frames).
(07nn
will
be
displayed
where
nn
is
the
frame
address.)
Press
Enter
.
(07nn
00
will
be
displayed.)
Note:
For
a
non-system
unit
frame,
the
display
on
the
addressed
frame
should
now
be
blinking
on
and
off.
For
a
system
unit,
press
an
arrow
key
(increment
or
decrement)
twice
to
display
the
ID
(first
07**
will
be
displayed
then
07nn
will
be
displayed,
where
nn
is
the
Configuration
ID).
Figure
3.
Control
Panel
Diagram
for
Function
A6
and
A8
d.
The
Configuration
ID
displayed
is
defined
as
follows:
Table
5.
Configuration
ID
ID
Model
81
FC
5074,
FC
5079,
FC
8093-002
84
FC
5078,
FC
0578
89
FC
5088,
FC
0588
8A
FC
5094,
FC
5294
8B
FC
5095
90
FC
5075
91
Model
800
or
810
without
an
expansion
unit
(FC
7116),
and
without
a
removable
processor
92
Model
800
or
810
without
an
expansion
unit
(FC
7116),
and
with
a
removable
processor
95
Model
800
or
810
with
an
expansion
unit
(FC
7116),
and
without
removable
processor
Analyze
hardware
problems
347