d.
Perform
the
following
if
the
new
power
supply
does
not
fix
the
problem:
1)
Reinstall
the
original
power
supply.
2)
Try
the
new
power
supply
in
each
of
the
other
positions
listed
in
the
table.
3)
If
the
problem
still
is
not
fixed,
reinstall
the
original
power
supply
and
go
to
the
next
FRU
in
the
list.
Table
23.
For
1xxx-11xx
SRCs
Unit
reference
code
Power
supply
1100
P01
1101
P02
1102
P03
1103
P04
1104
P05
1105
P06
This
ends
the
procedure.
3.
Is
the
SRC
1xxx-13xx?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following:
a.
Find
the
unit
reference
code
in
the
following
tables
to
determine
the
failing
power
supply.
b.
Refer
to
for
the
location
and
part
number
of
the
failing
item.
c.
Replace
the
failing
power
supply.
d.
Perform
the
following
if
the
new
power
supply
does
not
fix
the
problem:
1)
Reinstall
the
original
power
supply.
2)
Try
the
new
power
supply
in
each
of
the
other
positions
listed
in
the
table.
3)
If
the
problem
still
is
not
fixed,
reinstall
the
original
power
supply
and
go
to
the
next
FRU
in
the
list.
Table
24.
For
SRC
1xxx-13xx
Unit
reference
code
Power
supply
1300
P01
1301
P02
1302
P03
1303
P04
1304
P05
1305
P06
This
ends
the
procedure.
4.
Is
the
SRC
1xxx-15xx
or
19xx?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following:
a.
Find
the
unit
reference
code
in
the
following
tables
to
determine
the
failing
power
supply.
b.
On
a
system
unit
with
the
dual
line
cord
feature
and
a
1xxx-1510,
1520,
1530,
1910
or
1920
SRC,
perform
before
replacing
parts.
c.
Refer
to
to
determine
the
location
and
part
number
of
the
failing
item.
d.
Replace
the
failing
power
supply.
Analyze
hardware
problems
439