PRC
in
Word
4
Indicated
status
3205
During
IPL
LIC
determined
that
the
loop
was
not
complete.
This
is
expected
if
there
are
no
I/O
towers
on
the
loop.
This
is
also
expected
if
one
of
the
I/O
towers
on
the
loop
is
an
FC
5077
migrated
tower
which
does
not
have
all
three
bus
adapter
cards
installed.
This
error
can
also
occur
when
a
tower,
shared
tower,
or
another
system
on
the
loop
did
not
complete
powering
on
by
the
time
LIC
on
this
system
checked
the
loop
for
errors.
As
a
result
of
that
you
may
see
this
error
in
the
Service
Action
Log
(SAL).
When
you
find
the
same
SRC
logged
against
the
same
resource
with
a
″
3206
″
or
″
3208
″
PRC
in
word
4,
from
the
same
IPL,
it
means
that
the
problem
no
longer
exists
and
the
SAL
entry
can
be
closed.
This
error
may
also
appear
in
the
SAL
if
any
I/O
towers
were
removed
from
the
loop,
but
the
HSL
I/O
Bridge
resources
of
those
towers
were
not
deleted
from
HSM.
The
service
procedure(s)
identified
with
the
SRC
that
sent
you
to
this
symbolic
FRU
will
help
you
determine
if
the
loop
is
functioning
correctly
or
if
service
is
required.
This
error
may
also
be
caused
by
a
problem
in
a
frame
or
unit
connected
to
the
HSL
loop.
Follow
the
service
procedures
for
this
SRC.
When
necessary,
you
may
be
directed
to
work
on
other
SRCs
before
returning
to
this
procedure.
For
models
introduced
after
version
5,
release
1,
this
error
can
be
caused
by
unsupported
SPD
migration
towers
being
placed
in
the
loop.
Remove
the
unsupported
towers
to
correct
the
problem.
3206
During
normal
operation
an
HSL
loop
recovered
its
redundant
path.
The
loop
is
now
complete.
3208
During
normal
operation
an
HSL
I/O
bridge
recovered
a
failed
link
on
the
loop.
3209
See
Indicated
status
for
PRC
in
Word
4,
3209
(See
page
below.
3210
An
HSL
link
switched
to
a
slower
speed.
The
link
is
designed
to
run
at
a
faster
speed.
If
there
is
a
FRU
list
in
the
SAL,
use
it
to
complete
the
repair
section.
If
there
is
no
FRU
list
in
the
SAL,
use
only
the
following
sections
of
the
procedure
below:
Determine
the
HSL
port
label
(See
page
Replace
the
link’s
failing
end
point
FRUs
(See
page
(replace
only
the
″
From
Frame
ID
″
End
Point
FRU)
Indicated
status
for
PRC
in
Word
4,
3209:
Recoverable
CRC
errors
have
occurred
on
the
loop.
This
error
requires
a
service
action.
An
HSL
cable
or
connection
must
be
exchanged.
Exchange
only
the
HSL
cable
that
appears
in
the
FRU
list
of
this
SRC
(BUSCBLX)
in
this
document.
If
you
are
working
from
the
SAL,
then
only
the
FRU(s)
required
for
this
error
will
be
displayed.
Choose
from
the
following
scenarios:
v
If
there
is
a
SAL
entry
with
a
cable
FRU
(BUSCBLX
in
the
part
number
field)
listed
with
a
loop
number,
frame
ID,
and
port
label
identified
with
the
cable
FRU,
then:
–
If
the
cable
is
optical,
it
is
possible
the
optical
connections
need
cleaning.
You
can
choose
to
clean
the
cable
connections
at
each
end
without
exchanging
the
cable.
Use
the
Symbolic
FRU
for
information
on
cleaning
the
connections.
If
you
choose
to
exchange
the
HSL
cable
you
have
identified,
see
–
If
the
cable
is
copper,
examine
the
screws
which
hold
the
connector
at
the
end
of
the
cable
identified
in
the
SRC
or
the
first
cable
location
listed
in
the
SAL
entry.
It
is
possible
to
get
CRC
errors
when
the
screws
are
not
tight.
You
can
choose
to
tighten
the
cable
connector
screws
without
exchanging
the
cable
only
if
they
are
loose.
Otherwise,
exchange
the
cable.
See
If
this
does
not
correct
the
problem,
replace
the
FRUs
in
the
SAL
one
at
a
time.
See
the
page
for
the
frame
on
which
you
are
working.
This
ends
the
procedure.
458
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation