Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
9001
I/O processor card detected device configuration error
Perform SDIOP-PIP33.
9002
I/O processor card detected device error
Perform SDIOP-PIP16.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
9008
I/O card does not support functions expected by devices
Perform SDIOP-PIP25.
9009
Call your next level of support for assistance
9010
Cache data associated with attached devices cannot be found
Perform SDIOP-PIP31.
9011
Cache data belongs to devices other than those attached
Perform SDIOP-PIP32.
9014
Mode jumper overridden due to cache data in conflicting mode
See JOVERRIDE.
9015
Mode jumper missing
See JMISSING.
9020 to 9021
Array not functional due to present hardware configuration.
Perform SDIOP-PIP20.
9022 to 9024
Array not functional due to present hardware configuration.
Perform SDIOP-PIP22.
9025
Disk unit is not supported at its physical location.
Perform SDIOP-PIP21.
9026
Array not functional due to present hardware configuration.
Perform SDIOP-PIP22.
9027
Array not functional due to present hardware configuration.
Perform SDIOP-PIP34.
9028
Incorrect hardware configuration change has been detected.
Reduce the number of arrays on IOP. Either move all devices in an array to
another IOP that supports arrays, or stop an array on this IOP.
9029
Incorrect hardware configuration change has been detected.
Contact your next level of support.
902F
Array addendum Product Activity Log entry
This entry contains additional array information for 90xx reference codes
when the array contains more than 10 array members. Use the 90xx entry
that occurred at the same time as this reference code as the starting point
for this problem.
2748, 2757, 2763, 2778, 2782, 5703
System Reference Codes
143