Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
8300
I/O processor card or Licensed Internal Code error
A microprocessor exception occurred on the I/O processor.
STORIOA
IOP
AJDGP01
8301
Not valid condition in I/O Processor Licensed Internal Code
The Licensed Internal Code found a condition that should not have
occurred.
8400
I/O processor Licensed Internal Code error
AJDGP01
9000
I/O processor card detected device error
9001
I/O processor card detected device configuration error
Perform SDIOP-PIP33.
9002
I/O processor card detected device error
Perform SDIOP-PIP16.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
9008
I/O card does not support functions expected by devices
Perform SDIOP-PIP25.
9009
Call your next level of support for assistance
9010
Cache data associated with attached devices cannot be found
Perform SDIOP-PIP19.
9011
Cache data belongs to devices other than those attached
Perform SDIOP-PIP19.
9012
IOP requires a cache adaptor card but cannot find it.
The cache adapter card is missing or broken.
Perform SDIOP-PIP29.
9013
The IOP and attached cache adaptor card are not compatible.
Perform SDIOP-PIP19.
9020 to 9021
Array not functional due to present hardware configuration.
Perform SDIOP-PIP20.
9022 to 9024
Array not functional due to present hardware configuration.
Perform SDIOP-PIP22.
9025
Disk unit is not supported at its physical location.
Perform SDIOP-PIP21.
9026 to 9027
Array not functional due to present hardware configuration.
Perform SDIOP-PIP22.
9028
Incorrect hardware configuration change has been detected.
Reduce the number of arrays on IOP. Either move all devices in an array to
another IOP that supports arrays, or stop an array on this IOP.
2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C, 286D, 286E, 286F, 5702
System Reference Codes
151