Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
9355
The data format is incorrect; the tape cannot be read
The tape unit has detected that the data format on the tape media is not
supported.
Clean the tape unit and retry the operation.
If the operation continues to fail, use a different tape cartridge.
ULYUSR1
MLYTMED
ULYCLN
86G9251
9500
I/O processor Licensed Internal Code error
If the system is operational, take a dump of the I/O processor data. For
more infomration, see the
iSeries Service Functions
information or ask your
next level of support for assistance.
9600
Equipment Check Failure on Library Device.
See library device service information to resolve the error.
LIBDEV
9800 to 9803
I/O processor successfully recovered from temporary error
No action required. This reference code is logged for information only.
9810
Problem analysis has determined a part should be replaced.
This reference code is used for ending Online Problem Analysis with a list
of failing items. (Information only)
9899
Problem analysis completed, the problem has been corrected.
This reference code is used for ending Online Problem Analysis when no
problem was found or the problem was corrected.
ULYFIXD
9900
Licensed Internal Code for tape unit was not upgraded
The I/O processor loading of Licensed Internal Code (LIC) to the
programmable tape drive was not completed.
The tape drive will continue to operate with the previous LIC. You may do
either of the following:
v
Wait for next IPL when the system will attempt to load the LIC for the
tape drive again.
v
Perform TU-PIP4 to reset the IOP and the tape drive. When the IOP is
reset, if the device has the wrong level of LIC, the IOP will attempt to
load the new LIC.
ULYWAIT
FF09
Licensed Internal Code for tape unit was not upgraded
The I/O processor loading of Licensed Internal Code (LIC) to the
programmable tape drive was not completed.
The tape drive will continue to operate with the previous LIC. You may do
either of the following:
v
Wait for next IPL when the system will attempt to load the LIC for the
tape drive again.
v
See the system service documentation to reset the IOP and the tape
drive. When the IOP is reset, if the device has the wrong level of LIC,
the IOP will attempt to load the new LIC.
ULYWAIT
9427
System Reference Codes
195