1.
Look at characters 5 through 8 of the top 16 character line of function 11 (4
rightmost characters of word 1). These 4 characters are the unit reference code.
2.
Find the unit reference code in the following table.
For more on the Failing Item column entries, see Table 2. Asynchronous
Communications Failing Items Details, which follows the reference code table
below.
Table 1. (B003) Asynchronous Communications Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
2321
Procedure error in Licensed Internal Code
CNGTEMP
2322
Data-set-ready error on modem interface
CNGTEMP
2340
Data-set-ready changed to not active; for information only
FI00704
CNGTHRS
FI00701
FI00719
3200
Clear-to-send state changed; error limit per 256 reached
FI00704
CNGTHRS
FI00701
FI00719
3201
Data-set-ready state changed; error limit per 256 reached
FI00704
CNGTHRS
FI00701
FI00719
3202
Clear-to-send state changed; error limit per 256 reached
FI00704
CNGTHRS
FI00701
FI00719
3203
Carrier-detect state changed; error limit per 256 reached
FI00704
CNGTHRS
FI00701
FI00719
3204
Call not completed; error limit per 256 reached
CNGTEL
GNGLINK
FI00705
FI00703
3205
Call completed with error; error limit per 256 reached
CNGTHRS
3206
Data-line-occupied error; error limit per 256 reached
3207
Abandon-call-retry error; error limit per 256 reached
FI00703
CNGTHRS
GNGLINK
FI00702
CNGTEL
3208
Present-next-digit error; error limit per 256 reached
FI00703
CNGTHRS
FI00702
FI00719
B003
202
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)