Failing Item
Description
Document Description
86G7750
Battery Power Unit Charger
Repair and Parts
86G8020
Battery Power Unit Charger
Repair and Parts
86G8040
Battery Power Unit
Repair and Parts
90H6287
Optical Converter
Repair and Parts
ACMODUL
AC Module
Problem Analysis; Symbolic FRU Isolation
AIRMOVR
Fan and Blower assemblies
Problem Analysis; Symbolic FRU Isolation
AJDG301
Vertical Licensed Internal Code.
Service Functions; APAR or LICTR
ALTMANL
Alternate Manual Required
Problem Analysis; Symbolic FRU Isolation
BACKPLN
Back Plane Unit
Problem Analysis; Symbolic FRU Isolation
BATCHGR
Battery Power Unit Charger
Problem Analysis; Symbolic FRU Isolation
BATRY
Battery Power Unit
Problem Analysis; Symbolic FRU Isolation
BKSPCN
SPCN card
Problem Analysis; Symbolic FRU Isolation
BUSPWR
Domain 29V Bus
Problem Analysis; Symbolic FRU Isolation
CBLALL
Cable Failure
Problem Analysis; Symbolic FRU Isolation
CLKCARD
Clock card
Problem Analysis; Symbolic FRU Isolation
CTLPNL
Control Panel
Problem Analysis; Symbolic FRU Isolation
DISKDRV
Disk Unit Power regulator
Problem Analysis; Symbolic FRU Isolation
DISKTRY
Disk unit tray
Problem Analysis; Symbolic FRU Isolation
DMREG
Domain Regulator
Problem Analysis; Symbolic FRU Isolation
I2CBUS
I2C Bus Part
Problem Analysis; Symbolic FRU Isolation
IDPART
Vital Product Data Parts
Problem Analysis; Symbolic FRU Isolation
INTRLCK
Interlock part
Problem Analysis; Symbolic FRU Isolation
PGDPART
Power Good Part
Problem Analysis; Symbolic FRU Isolation
PWROC
Power Supply overcurrent
Problem Analysis; Symbolic FRU Isolation
PWRREG
Regulator.
Problem Analysis; Symbolic FRU Isolation
PWRSPLY
Power Supply
Problem Analysis; Symbolic FRU Isolation
RMDEV
Disk Unit or Removable Media Device
Problem Analysis; Symbolic FRU Isolation
SPNLCRD
SPCN panel card
Problem Analysis; Symbolic FRU Isolation
SVCPROC
Service Processor Card
Problem Analysis; Symbolic FRU Isolation
TWRCARD
Card enclosure or backplane
Problem Analysis; Symbolic FRU Isolation
UPSUNIT
UPS unit part
Problem Analysis; Symbolic FRU Isolation
VPDPART
VPD Communication Part
Problem Analysis; Symbolic FRU Isolation
(1xxx) SPCN Reference Codes for Models 870 and 890
If you reached this point from the Service Action Log (SAL), return to the SAL and
display the failing item information for this entry. Go directly to the symbolic FRU
specified in the failing items list.
Note:
On Models 870 and 890, the two rightmost characters on the control panel
display (following the dash) are the table identifier (-xx). The table identifier
is required to determine which Model 870 or 890 reference code table
applies to the unit reference code recorded.
1xxx
120
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)