(1xxx) System Power Control Network (SPCN) Reference Codes
The system power control network (SPCN) detected a failure.
Note:
The second and third characters of the SRC indicate the frame number of
the failing unit.
1.
Look at the four rightmost characters of the SRC for Function 11 or Function 5.
These characters are the unit reference code.
2.
Find the unit reference code in the following tables, depending on the system
model.
Note:
xSeries Server (formerly Netfinity) frames will have only the frame
number flashing on the failing unit’s PCI (SPCN) card assembly which is
visible after removing the cover.
Choose the model you are working on:
v
v
v
v
(1xxx) SPCN Reference Codes for Models 270 and 820
For details on the Failing Item column entries, see the SPCN Failing Items Detail
table.
Table 1. SPCN reference codes for Models 270 and 820
:
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
00A0
SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
00A1
Regulator 1 has been turned off by system
No action required. This reference code is logged for information only.
00A2
Regulator 2 has been turned off by system
No action required. This reference code is logged for information only.
00A3
Regulator 3 has been turned off by system
No action required. This reference code is logged for information only.
00A4
Regulator 4 has been turned off by system
No action required. This reference code is logged for information only.
00A5
Regulator 5 has been turned off by system
No action required. This reference code is logged for information only.
00A6
Regulator 6 has been turned off by system
No action required. This reference code is logged for information only.
1xxx
10