Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
3002
Addressed device is not responding
3010
Disk device returned wrong response to IOP
3020
Storage subsystem configuration error
If an MES is being installed, verify the configuration.
3029
A device replacement has occurred
No action required. This reference code is logged for information only.
3100
Fibre Channel interface error occurred
3109
IOP timed out a disk command
34FF
Format in progress
The device indicated that a format is in progress. When the format is
complete, the device should be useable. No action is required. This
reference code is logged for information only.
FFF3
Disk media format bad
FFF4
Disk device problem
FFF5
Disk sector read error
FFF6
Disk device detected recoverable error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see “Hardware Service Manager” in the
iSeries Service
Functions
.
FFFA
Disk device wrong response was recovered by the IOP
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see “Hardware Service Manager” in the
iSeries Service
Functions
.
FFFE
Temporary Fibre Channel interface error
A disk unit service action is recommended only if the Service Action Log
contains an entry for this reference code. For more information about the
Service Action Log, see “Hardware Service Manager” in the
iSeries Service
Functions
.
Table 2. Disk Unit Failing Items Details
Failing Item
Description
Document Description
FCDEV
Fibre Channel device
Problem Analysis; Symbolic FRU Isolation
2105