v
Yes
:
Call
you
next
level
of
support.
This
ends
the
procedure.
15.
Exchange
the
card
multi-adapter
bridge’s
FRU
at
the
card
position
that
you
determined
for
it.
To
determine
the
remove
and
replace
procedure
for
the
multi-adapter
bridge’s
FRU,
locate
the
FRU’s
card
position
in
the
FRU
locations
and
failing
items
table
for
the
frame
type
that
you
recorded.
FRU
locations
and
failing
items
tables
are
in
16.
Install
all
IOPs
and
IOAs
in
their
original
positions.
17.
Power
on
the
system
or
partition.
Does
the
SRC
or
failure
that
sent
you
to
this
procedure
occur?
v
No
:
Perform
This
ends
the
procedure.
v
Yes
:
Call
your
next
level
of
support.
This
ends
the
procedure.
Bus
PIP
PCIBUS-PIP1:
For
use
by
authorized
service
providers.
PCIBUS-PIP1:
PCI
Adapter
Card
Position
Procedure.
1.
If
you
were
sent
to
this
procedure
with
a
specific
Direct
Select
Address
(DSA),
then
use
it.
Otherwise,
use
the
DSA
in
word
7
of
the
B6xx
SRC,
see
(in
the
Bus
PIP
overview
topic)
for
help
in
locating
the
DSA.
2.
Perform
the
following:
a.
Record
the
bus
number
value,
BBBB,
in
the
DSA.
See
(in
the
Bus
PIP
overview
topic)
for
help
in
locating
the
BBBB
value
in
the
DSA.
You
must
convert
the
BBBB
value
to
decimal
.
b.
Search
for
the
decimal
bus
number
in
HSM
or
the
System
Configuration
Listing
to
determine
which
frame
or
I/O
tower
contains
the
failing
item.
From
the
Hardware
Service
Manager
screen
select
Logical
Hardware
Resources
—>
System
Bus
resources
.
Move
the
cursor
to
a
system
bus
object
and
select
Display
Detail
.
Do
this
for
each
bus
until
you
find
the
bus
on
which
you
are
working.
c.
Record
the
frame
or
tower
type.
3.
Record
the
Cc
value
in
the
DSA.
See
for
help
in
locating
the
Cc
value
in
the
DSA.
4.
Is
the
Cc
value
greater
than
00?
v
No
:
The
multi-adapter
bridge
and
the
multi-adapter
function
number
are
not
identified.
Record
that
the
multi-adapter
bridge
is
not
identified
in
the
DSA.
The
card
slot
cannot
be
identified
using
the
DSA.
Go
to
step
8
(See
page
v
Yes
:
Is
the
right-most
character
of
the
Cc
value
’F’?
–
No
:
Continue
with
the
next
step.
–
Yes
:
Only
the
multi-adapter
bridge
number
is
identified.
Record
the
multi-adapter
bridge
number
(the
leftmost
character
of
the
Cc
value)
for
later
use.
The
card
slot
cannot
be
identified
using
the
DSA.
Go
to
step
8
(See
page
5.
Is
SST/DST
available?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
12
(See
page
6.
Use
the
(located
in
the
Bus
PIP
Overview
topic)
with
the
BBBB
and
Cc
values
that
you
recorded
to
identify
the
card
position.
Use
the
card
position
table
that
matches
the
frame
or
I/O
tower
type
that
you
recorded.
7.
Return
to
the
procedure,
Failing
Item,
or
symbolic
FRU
that
sent
you
here.
This
ends
the
procedure.
8.
Perform
the
following:
Analyze
hardware
problems
99