v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
12
(See
page
9.
Does
either
the
Disk
Configuration
Error
Report,
the
Disk
Configuration
Attention
Report,
or
the
Disk
Configuration
Warning
Report
display
appear
with
one
of
the
following
listed?
v
Missing
disk
units
in
the
configuration
v
Missing
mirror
protection
disk
units
in
the
configuration
v
Device
parity
protected
units
in
exposed
mode
–
Yes
:
Continue
with
the
next
step.
–
No
:
Go
to
step
11
(See
page
10.
Select
option
5
,
press
F11
,
and
then
press
Enter
to
display
details.
Does
an
SRC
appear
in
the
Reference
Code
column?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
12
(See
page
11.
Look
at
all
the
Product
activity
logs
by
selecting
Product
activity
log
under
DST.
Is
an
SRC
logged
as
a
result
of
this
IPL?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
last
device
you
disconnected
is
the
failing
item.
Exchange
the
failing
device
and
reconnect
the
devices
that
were
disconnected
previously.
Note:
Before
exchanging
a
disk
drive,
you
should
attempt
to
save
customer
data
(see
the
This
ends
the
procedure.
12.
Record
the
SRC
on
the
Problem
summary
form
(see
Is
the
SRC
the
same
one
that
sent
you
to
this
procedure?
v
No
:
Continue
with
the
next
step.
v
Yes
:
The
last
device
you
disconnected
is
not
the
failing
item.
a.
Leave
the
device
disconnected
and
go
to
step
7
(See
page
to
continue
isolation.
b.
If
you
have
disconnected
all
devices
that
are
identified
by
FI
code
FI01106
except
the
load-source
disk
unit,
reconnect
all
devices.
Then,
go
to
step
15
(See
page
13.
Does
either
the
Disk
Configuration
Error
Report,
the
Disk
Configuration
Attention
Report,
or
the
Disk
Configuration
Warning
Report
display
appear
with
one
of
the
following
listed?
v
Missing
disk
units
in
the
configuration
v
Missing
mirror
protection
disk
units
in
the
configuration
v
Device
parity
protected
units
in
exposed
mode
–
Yes
:
Continue
with
the
next
step.
–
No
:
Use
the
reference
code
to
correct
the
problem.
This
ends
the
procedure.
14.
Select
option
5
,
press
F11
,
and
then
press
Enter
to
display
details.
Are
all
the
reference
codes
0000?
v
No
:
Use
the
reference
code
to
correct
the
problem.
This
ends
the
procedure.
v
Yes
:
The
last
device
you
disconnected
is
the
failing
item.
a.
Reconnect
all
devices
except
the
failing
item.
b.
Before
exchanging
a
disk
unit,
go
to
the
disk
unit
for
the
model
you
are
working
on.
This
ends
the
procedure.
15.
Was
disk
unit
1
(the
load-source
disk
unit)
a
failing
item
that
FI
code
FI01106
identified?
Analyze
hardware
problems
107