v
Yes
:
The
failing
items
that
FI
code
FI01106
identified
are
not
failing.
The
load-source
disk
unit
may
be
failing.
Use
the
original
SRC
and
exchange
the
failing
items,
starting
with
the
highest
probable
cause
of
failure
(see
the
failing
item
list
for
this
reference
code
in
the
tables).
If
the
failing
item
list
contains
FI
codes,
see
to
help
determine
part
numbers
and
location
in
the
system.
This
ends
the
procedure.
v
No
:
The
failing
items
that
FI
code
FI01106
identified
are
not
failing.
Use
the
original
SRC
and
exchange
the
failing
items,
starting
with
the
highest
probable
cause
of
failure
(see
the
failing
item
list
for
this
reference
code
in
the
tables).
If
the
failing
item
list
contains
FI
codes,
see
to
help
determine
part
numbers
and
location
in
the
system.
This
ends
the
procedure.
Intermittent
PIPs
For
use
by
authorized
service
providers.
Use
these
procedures
to
correct
an
intermittent
problem,
if
other
problem
analysis
steps
or
tables
sent
you
here.
Only
perform
the
procedures
that
apply
to
your
system.
Read
all
safety
procedures
before
servicing
the
system.
Observe
all
safety
procedures
when
performing
a
procedure.
Unless
instructed
otherwise,
always
power
off
the
system
or
expansion
tower
where
the
FRU
is
located,
(see
before
removing,
exchanging,
or
installing
a
field-replaceable
unit
(FRU).
DANGER
To
prevent
power
from
switching
on
automatically
during
service
procedures,
select
manual
or
secure
mode
on
the
system
unit
control
panel
or
disconnect
the
cables
that
connect
to
J15
and
J16
on
the
frame
being
serviced.
(RSFTD211)
Intermittent
PIP
procedures:
INT-PIP3
External
noise
on
ac
voltage
lines:
For
use
by
authorized
service
providers.
Electrical
noise
on
incoming
ac
voltage
lines
can
cause
various
system
failures.
The
most
common
source
of
electrical
noise
is
lightning.
108
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation