There
is
not
enough
main
storage
capacity.
For
details
about
how
much
more
capacity
is
required,
see
the
″
Insufficient
Main
Storage
Capacity
″
screen,
which
is
displayed
when
the
system
is
IPLed
in
manual
mode.
Typically,
this
error
occurs
when
you
have
moved
memory
between
logical
partitions,
and
one
partition
no
longer
has
a
sufficient
amount
of
main
storage.
This
ends
the
procedure.
0099:
A
Licensed
Internal
Code
program
error
occurred.
Ask
your
next
level
of
support
for
assistance.
This
ends
the
procedure.
LIC-PIP12:
For
use
by
authorized
service
providers.
Use
this
procedure
to
isolate
an
Independent
Auxiliary
Storage
Pool
(IASP)
vary
on
failure.
Message
CPDB8E0
occurred
if
the
user
attempted
to
vary
on
the
IASP.
Read
the
before
continuing
with
this
procedure.
How
to
find
the
cause
code:
1.
If
the
system
has
logical
partitions,
perform
this
procedure
from
the
logical
partition
that
reported
the
problem.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Were
you
given
a
cause
code
by
another
procedure?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Use
the
cause
code
given
by
the
other
procedure.
Then,
go
to
step
4
(See
page
of
this
procedure.
3.
Look
at
the
characters
in
word
3.
You
can
obtain
these
characters
by
doing
the
following:
a.
On
the
command
line,
enter
STRSST
(the
Start
System
Service
Tools)
command.
If
you
cannot
get
to
SST,
use
function
21
to
get
to
DST.
See
in
the
iSeries
Service
Functions
.
Do
not
IPL
the
system
to
get
to
DST.
b.
On
the
Start
Service
Tools
Sign
On
display,
type
in
a
User
ID
with
QSRV
authority
and
Password.
c.
Select
Start
a
Service
Tool
—>
Hardware
Service
Manager
—>
Work
with
service
action
log
.
d.
On
the
Select
Timeframe
display,
change
the
From:
Date
and
Time
to
a
date
and
time
prior
to
when
the
user
attempted
to
vary
on
the
IASP.
e.
Search
for
a
B6005094
system
reference
code
that
occurred
at
the
time
the
user
attempted
to
vary
on
the
IASP.
Display
the
failing
item
information
for
this
entry.
f.
Select
the
function
key
for
Additional
details
.
g.
The
4
leftmost
characters
of
word
3
is
the
cause
code
to
be
used
in
this
procedure.
4.
Find
the
cause
code
below.
0002:
Disk
units
are
missing
from
the
IASP
disk
configuration.
1.
Have
you
installed
a
new
disk
enclosure
in
a
disk
unit
and
not
restored
the
data
to
the
disk
unit?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Ignore
SRC
A600
5094.
Continue
with
the
disk
unit
exchange
recovery
procedure.
See
″
Disk
Service
Support
″
in
This
ends
the
procedure.
2.
Use
words
1-9
from
the
information
in
the
Service
Action
Log
to
determine
the
disk
unit
that
is
missing
from
the
configuration:
v
Word
4
contains
the
IOP
direct
select
address.
v
Word
5
contains
the
unit
address.
v
Word
6
contains
the
disk
unit
type,
level
and
model
number.
v
Word
7
contains
the
disk
unit
serial
number.
134
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation