v
Yes
:
Exchange
the
failing
ac
line
cord.
This
ends
the
procedure.
v
No
:
Perform
the
following:
a.
Inform
the
customer
that
the
ac
voltage
at
the
power
outlet
is
not
correct.
b.
Reconnect
the
ac
line
cords
to
the
power
outlet.
This
ends
the
procedure.
8.
Is
the
SRC
1xxx-00AC?
v
No
:
Continue
with
the
next
step.
v
Yes
:
On
a
Model
825,
the
00AC
reference
code
can
be
caused
by
the
cover
on
the
processor
enclosure
not
being
installed
(see
or
a
faulty
interlock
switch
assembly
(see
the
remove
and
replace
procedure,
and
the
for
the
part
number).
For
other
Models
or
FCs,
exchange
the
tower
card
on
the
failing
frame
(see
symbolic
FRU
This
ends
the
procedure.
9.
Perform
the
following
for
SRC
1xxx-1500,
1510,
1520,
or
1530:
a.
Determine
the
following
locations:
v
Model
820
with
dual
line
cord
(See
–
(SRC
1xxx
1510,
1520):
ac
line
cord
1.
–
(SRC
1xxx
1530):
ac
line
cord
2.
v
Model
825
with
dual
line
cord
(See
–
(SRC
1xxx
1510):
line
cord
1
–
(SRC
1xxx
1520):
line
cord
2.
v
FC
5074,
FC
5079
(See
or
–
(SRC
1xxx
1510):
the
ac
jumper
cord
connected
to
P01
and
the
AC
module.
–
(SRC
1xxx
1520):
the
ac
jumper
cord
connected
to
P02
and
the
AC
module.
v
FC
5078,
FC
0578
(See
and
Figure
2
(See
page
–
(SRC
1xxx
1510):
the
ac
jumper
cord
connected
to
P02
and
the
AC
module.
–
(SRC
1xxx
1520):
the
ac
jumper
cord
connected
to
P01
and
the
AC
module.
v
FC
5088,
FC
0588
(See
and
Figure
2
(See
page
–
(SRC
1xxx
1510):
the
ac
jumper
cord
connected
to
power
supply
P02
and
the
AC
module.
–
(SRC
1xxx
1520):
the
ac
jumper
cord
connected
to
power
supply
P01
and
the
AC
module.
v
FC
5095,
FC
0595
(See
–
(SRC
1xxx
1510):
ac
line
cord
1.
–
(SRC
1xxx
1520):
ac
line
cord
2
v
FC
5094,
FC
9094
(See
Figure
1
(See
page
below)
–
(SRC
1xxx
1500):
the
ac
jumper
cord
connected
to
P00
and
the
AC
module.
–
(SRC
1xxx
1510):
the
ac
jumper
cord
connected
to
P01
and
the
AC
module.
–
(SRC
1xxx
1520):
the
ac
jumper
cord
connected
to
P02
and
the
AC
module.
–
(SRC
1xxx
1530):
the
ac
jumper
cord
connected
to
P03
and
the
AC
module.
Figure
1.
Dual
line
cord
drawing
for
FC
5094
and
FC
9094
178
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation