5.
Perform
an
IPL
to
DST.
See
in
the
iSeries
Service
Functions
information.
Does
an
SRC
appear
on
the
control
panel?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
9
(See
page
6.
Does
either
the
Disk
Configuration
Error
Report,
the
Disk
Configuration
Attention
Report,
or
the
Disk
Configuration
Warning
Report
display
appear
on
the
console?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Select
option
5
,
press
F11
,
then
press
Enter
to
display
the
details.
Then,
choose
from
the
following
options:
–
If
all
of
the
reference
codes
are
0000,
go
to
and
use
cause
code
0002.
–
If
any
of
the
reference
codes
are
not
0000,
go
to
step
9
(See
page
and
use
the
reference
code
that
is
not
0000.
Note:
Use
the
characters
in
the
Type
column
to
find
the
correct
reference
code
table.
7.
Look
at
the
product
activity
log.
See
for
details).
Is
an
SRC
logged
as
a
result
of
this
IPL?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
problem
cannot
be
isolated
any
more.
Use
the
original
SRC
and
exchange
the
failing
items.
Start
with
the
highest
probable
cause
of
failure
(see
the
failing
item
list
for
this
reference
code
in
and
If
the
failing
item
list
contains
FI
codes,
see
to
help
determine
part
numbers
and
location
in
the
system.
This
ends
the
procedure.
8.
Does
either
the
Disk
Configuration
Error
Report,
the
Disk
Configuration
Attention
Report,
or
the
Disk
Configuration
Warning
Report
display
appear
on
the
console?
v
No
:
Look
at
the
product
activity
log.
See
for
details.
Is
an
SRC
logged
as
a
result
of
this
IPL?
–
Yes
:
Continue
with
the
next
step.
–
No
:
The
problem
is
corrected.
This
ends
the
procedure.
v
Yes
:
Select
option
5
,
press
F11
,
then
press
Enter
to
display
the
details.
Then,
choose
from
the
following
options:
–
If
all
of
the
reference
codes
are
0000,
go
to
and
use
cause
code
0002.
–
If
any
of
the
reference
codes
are
not
0000,
go
to
step
9
(See
page
and
use
the
reference
code
that
is
not
0000.
Note:
Use
the
characters
in
the
Type
column
to
find
the
correct
reference
code
table.
9.
Record
the
SRC
on
the
Problem
summary
form
(see
Are
the
SRC
and
unit
reference
code
(URC)
the
same
ones
that
sent
you
to
this
procedure?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Use
the
new
SRC
or
reference
code
to
correct
the
problem.
See
the
This
ends
the
procedure.
10.
Perform
the
following:
a.
Power
off
the
system
or
expansion
tower
(see
b.
Exchange
the
FRUs
in
the
failing
item
list
for
the
SRC
you
have
now.
Start
with
the
highest
probable
cause
of
failure
(see
the
failing
item
list
for
this
reference
code
in
the
System
reference
188
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation