v
If
the
I/O
adapter
is
attached
to
an
auxiliary
cache
I/O
adapter,
ensure
that
the
SCSI
cable
on
the
last
port
of
the
new
replacement
storage
I/O
adapter
is
connected
to
the
auxiliary
cache
I/O
adapter.
For
a
list
of
auxiliary
cache
I/O
adapters,
see
the
This
ends
the
procedure.
SDIOP-PIP31:
For
use
by
authorized
service
providers.
Cache
data
associated
with
the
attached
devices
cannot
be
found.
You
were
sent
to
this
procedure
from
URC
9010.
1.
If
the
system
has
logical
partitions,
perform
this
procedure
from
the
logical
partition
that
reported
the
problem.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Has
the
system
been
powered
off
for
several
days?
v
No
:
Go
to
step
4
(See
page
v
Yes
:
The
cache
battery
pack
may
be
depleted.
Do
NOT
replace
the
I/O
adapter
or
the
cache
battery
pack.
Reclaim
the
cache
storage.
See
Continue
with
the
next
step.
Note:
When
an
auxiliary
cache
I/O
adapter
connected
to
the
storage
I/O
adapter
logs
a
9055
SRC
in
the
Product
Activity
Log,
the
reclaim
does
not
result
in
lost
sectors.
Otherwise,
the
reclaim
does
result
in
lost
sectors,
and
the
system
operator
may
want
to
restore
data
from
the
most
recent
saved
tape
after
you
complete
the
repair.
3.
Does
the
IPL
complete
successfully?
v
No
:
Contact
your
next
level
of
support.
This
ends
the
procedure.
v
Yes:
This
ends
the
procedure.
4.
Remove
the
I/O
adapter.
Install
the
new
replacement
storage
I/O
adapter
with
the
following
parts
installed
on
it:
Note:
Label
all
parts
(both
old
and
new)
before
moving
them.
v
The
cache
directory
card
from
the
original
storage
I/O
adapter.
See
v
The
removable
cache
card
from
the
original
storage
I/O
adapter
(this
applies
to
only
some
2780
I/O
adapters).
See
v
If
the
I/O
adapter
is
attached
to
an
auxiliary
cache
I/O
adapter,
ensure
that
the
SCSI
cable
on
the
last
port
of
the
new
replacement
storage
I/O
adapter
is
connected
to
the
auxiliary
cache
I/O
adapter.
For
a
list
of
auxiliary
cache
I/O
adapters,
see
5.
Has
a
new
9010
or
9050
SRC
occurred
in
the
Service
Action
Log?
v
No
:
Go
to
step
8
(See
page
v
Yes
:
Continue
with
the
next
step.
6.
Was
the
new
SRC
9050?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Contact
your
next
level
of
support.
This
ends
the
procedure.
7.
The
new
SRC
was
9010.
Reclaim
the
cache
storage.
See
Note:
When
an
auxiliary
cache
I/O
adapter
that
is
connected
to
the
storage
I/O
adapter
logs
a
9055
SRC
in
the
Product
Activity
Log,
the
reclaim
does
not
result
in
lost
sectors.
Otherwise,
the
reclaim
does
result
in
lost
sectors,
and
the
system
operator
might
want
to
restore
data
from
the
most
recent
saved
tape
after
you
complete
the
repair.
8.
Remove
the
I/O
adapter.
Install
the
new
replacement
storage
I/O
adapter
that
has
the
following
parts
installed
on
it:
v
The
cache
directory
card
from
the
new
storage
I/O
adapter.
See
Analyze
hardware
problems
209