18.
Perform
the
following:
a.
Press
F12
to
return
to
the
Logical
Hardware
Resources
on
System
Bus
display.
b.
Select
Resources
associated
with
IOP
for
the
IOP
you
reset.
Did
the
IOP
detect
the
tape
unit?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
IOP
did
not
detect
the
tape
unit.
Consider
the
following:
–
Ensure
that
the
tape
unit
is
powered
on
and
that
the
signal
cables
are
connected
correctly.
If
you
find
and
correct
a
power
or
a
signal
cable
problem,
return
to
step
16
(See
page
–
The
tape
unit
may
be
failing.
Go
to
the
tape
unit
service
information
and
perform
the
procedures
for
analyzing
device
problems.
If
you
find
and
correct
a
tape
unit
problem,
return
to
step
16
(See
page
–
If
none
of
the
above
are
true,
ask
your
next
level
of
support
for
assistance.
This
ends
the
procedure.
19.
Press
F3
until
the
Exit
System
Service
Tools
display
appears.
Then
press
Enter
.
20.
Was
automatic
configuration
Off
before
you
performed
step
15
(See
page
v
Yes
:
Continue
with
the
next
step.
v
No
:
This
ends
the
procedure.
21.
Enter
CHGSYSVAL
QAUTOCFG
’0’
(the
Change
System
Value
command)
on
the
command
line
to
reset
QAUTOCFG
to
its
initial
value.
This
ends
the
procedure.
TU-PIP6:
For
use
by
authorized
service
providers.
Use
this
procedure
to
isolate
a
Device
Not
Found
message
during
installation
from
an
alternate
device.
There
are
several
possible
causes:
v
The
alternate
installation
device
was
not
correctly
defined.
v
The
alternate
installation
device
was
not
made
ready.
v
The
alternate
installation
device
does
not
contain
installation
media.
v
The
alternate
installation
device
is
not
powered
on.
v
The
alternate
installation
device
is
not
connected
properly.
v
There
is
a
hardware
error
on
the
alternate
installation
device
or
the
attached
I/O
processor.
Read
the
before
continuing
with
this
procedure.
1.
If
the
system
has
logical
partitions,
perform
this
procedure
from
the
logical
partition
that
reported
the
problem.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Is
the
device
that
you
are
using
for
alternate
installation
defined
as
the
alternate
installation
device?
v
Yes
:
Is
the
alternate
installation
device
ready?
–
Yes
:
Continue
with
the
next
step.
–
No
:
Make
the
alternate
installation
device
ready
and
retry
the
alternate
installation.
This
ends
the
procedure.
v
No
:
Correct
the
alternate
installation
device
information
and
retry
the
alternate
installation.
This
ends
the
procedure.
3.
Is
there
installation
media
in
the
alternate
installation
device?
v
Yes
:
Is
the
alternate
installation
device
an
external
device?
–
Yes
:
Continue
with
the
next
step.
–
No
:
Go
to
step
6
(See
page
234
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation